Quality-control scheme for blood glucose measured outside the laboratory.
نویسندگان
چکیده
We propose a quality-control (QC) scheme to evaluate the performance of blood glucose estimates made with a reflectometer in hospital wards or at home. We constructed a chart illustrating the comparison by regression analysis of the results of 254 reflectometer readings (y) and simultaneous capillary blood glucose analyses in the laboratory (x). Arbitrary acceptance limits around the regression line (y = 0.5 + 0.87x; r = 0.97, Sy/x = 0.8 mmol/L) were established, based on the mean +/- 2 SD of the reflectometer readings of a series of classes of 1.1 mmol/L interval, made with the results from the laboratory analyzer. Each ward using a reflectometer is provided with the QC chart, and the first blood glucose estimation with the reflectometer on each working shift is controlled by re-assay in the laboratory. If the reflectometer reading is outside the limits, the next glucose estimation is also re-assayed. If two consecutive readings are outside the limits, the reflectometer procedure is considered to be failing, the instrument's readings are not used for medical decisions, and remedial action is taken. The chart can also be used as a teaching tool for training the patients or the nurses and to evaluate individual performance.
منابع مشابه
Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملExperience of a quality assessment scheme for non-laboratory glucose meters.
In late 1989 a quality assessment scheme was introduced for glucose meters at 12 non-laboratory sites in a unit of management. The overall monthly imprecision of the meters varied from 3.4% to 17.1%, the highest coefficients of variation being recorded for glucose concentrations outside the range 3-20 mmol/l. In the same period 37% of results fell outside +/- 10% of laboratory set target limits...
متن کاملQuality assessment of blood glucose monitors in use outside the hospital laboratory.
The quality of analytical results required in clinical practice is generally dictated by analytical rather than clinical criteria. The increasing availability of analytical technology that can be used outside the hospital laboratory challenges this situation. In an attempt to highlight this dilemma one method of glucose analysis outside the laboratory has been assessed using a pilot external qu...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 33 7 شماره
صفحات -
تاریخ انتشار 1987