Evaluation of an auto-nCPAP device based on snoring detection.
نویسندگان
چکیده
We evaluated an auto-nasal continuous positive airway pressure (nCPAP) prototype (MC+; SEFAM, Nancy, France) in which apnoea/hypopnoea detection was disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The device was tested in 15 previously untreated obstructive sleep apnoea patients during a night with polysomnography. We observed that a single night of auto-nCPAP improved the apnoea/hypnoea index (AHI) (12 +/- 21 vs 51 +/- 31 disordered breathing events.h-1 of sleep (mean +/- SD)), the awakening-arousal index (13 +/- 20 vs 40 +/- 26 arousals.h-1 of sleep), and duration of slow wave sleep (102 +/- 49 vs 71 +/- 56 min) but not of rapid eye movement (REM) sleep (55 +/- 31 vs 64 +/- 38 min). Auto-nCPAP was effective (apnoea/hypopnoea and arousal indices < 10 events.h-1) in all but three patients. Auto-nCPAP was ineffective in one patient, whose obstructive respiratory events were not preceded by nasal mask pressure vibration detection, and in two patients who were quasi-permanent mouth breathers. Snoring detection may be effective in sleep apnoea syndrome with heavy snoring and without permanent mouth breathing, during the first night of nasal continuous positive airway pressure treatment.
منابع مشابه
CPAP titration by an auto-CPAP device based on snoring detection: a clinical trial and economic considerations.
This study aimed to assess the ability of an auto-nasal continuous positive airway pressure (nCPAP) device (REM + auto; NPBFD, Nancy, France) to predict the optimal constant nCPAP level. The apnoea/hypopnoea detection facility of the auto-nCPAP device was deliberately disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The auto-nCPAP device was tested on ...
متن کاملSnoring detection during auto-nasal continuous positive airway pressure.
A bench study using an artificial lung model was performed to evaluate the snoring detection sensitivity of six (commercially available) auto-nasal continuous positive airway pressure (NCPAP) devices. Snoring was simulated by a loudspeaker connected to the lung model and abruptly activated during 1 s of each inspiratory period to induce pressure oscillation. The oscillation frequencies chosen w...
متن کاملChanges in snoring characteristics after 30 days of nasal continuous positive airway pressure in patients with non-apnoeic snoring: a controlled trial.
BACKGROUND A study was performed to evaluate the effect of discontinuation of nasal continuous positive airway pressure (NCPAP) treatment on snoring characteristics. METHODS Eighteen non-apnoeic snoring subjects were randomly allocated to either a no treatment control group or an NCPAP treatment group. The control group was studied twice (baseline and day 30 of follow up). In the NCPAP group ...
متن کاملEvaluation of the Upper Airway in Patients with Snoring and OSA
Snoring and obstructive sleep apnoea (OSA) both exhibit multilevel upper airway obstruction. The Importance of evaluating the dynamics of the obstructing upper airway cannot be emphasised enough. Accurate assessment and evaluation of the upper airway could potentially lead to improved surgical and non-surgical treatment outcomes. Most of these patients would have undergone an ambulatory sleep s...
متن کاملEfficacy and cost of home-initiated auto-nCPAP versus conventional nCPAP.
STUDY OBJECTIVES To compare in a multicenter prospective study the efficacy and cost of conventional nasal continuous positive airway pressure (nCPAP) initiated at the sleep laboratory versus auto-nCPAP initiated at home. DESIGN Patients with severe obstructive sleep apnea syndrome (OSAS) were randomized to treatment with either the REM+ auto device in constant mode at the effective pressure ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 9 9 شماره
صفحات -
تاریخ انتشار 1996