Assessment of internal thoracic artery patency with transesophageal echocardiography during coronary artery bypass graft surgery.

نویسندگان

  • Masahiko Kuroda
  • Hiroshi Hamada
  • Masashi Kawamoto
  • Kazumasa Orihashi
  • Taijiro Sueda
  • Masaya Otsuka
  • Osafumi Yuge
چکیده

OBJECTIVE The purpose of this study was to evaluate intraoperative transesophageal echocardiography (TEE) for assessing patency of internal thoracic artery grafts. DESIGN A retrospective study. SETTING A university hospital. PARTICIPANTS Fifty-one consecutive patients who underwent coronary artery bypass graft (CABG) surgery using the left internal thoracic artery (LITA)-to-left coronary artery were examined postoperatively with coronary angiography (CAG). INTERVENTIONS None. MEASUREMENT AND MAIN RESULTS The authors measured blood flow velocity using TEE after anastomosis of a LITA graft. Intraoperative TEE findings and routine CAG results were compared to evaluate the quality of TEE assessment. The LITA was detected in 45 of 51 patients (88%) intraoperatively with TEE. Peak and mean velocities and velocity time integral ratios were determined by dividing each diastolic value by its corresponding systolic value. The peak velocity ratio was 0.51 +/- 0.04 (range, 0.40-0.59) in the presence of stenosis and 1.14 +/- 0.10 (range, 0.58-3.87) in its absence (p = 0.0289), whereas mean velocity ratios were 0.62 +/- 0.05 (range, 0.45-0.72) and 1.27 +/- 0.10 (range, 0.66-4.08) (p = 0.0223), respectively, and velocity time integral ratios were 0.83 +/- 0.09 (range, 0.64-1.05) and 2.69 +/- 0.29 (range, 0.91-8.35) (p = 0.0224), respectively. The critical values for peak and mean velocities and velocity time integral ratios were 0.60, 0.73, and 1.06, respectively, whereas the sensitivity for each was 100% and the specificity was 92%, 94%, and 89%, respectively. CONCLUSIONS The authors concluded that the intraoperative assessment of LITA patency with TEE was a markedly useful and powerful tool for anesthesiologists during CABG surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Descending aortic pulsed wave Doppler can predict changes in cardiac output during off-pump coronary artery bypass surgery.

Retraction and stabilization of the heart can induce rapid and large changes in the hemodynamic state during off-pump coronary artery bypass graft surgery (OPCABG). We aimed to determine if Doppler measurement of flow in the descending artery with transesophageal echocardiography (TEE) can provide a beat-to-beat assessment of changes in cardiac output (CO) in 26 OPCABG patients. Simultaneous me...

متن کامل

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.

OBJECTIVE To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tes...

متن کامل

Intraoperative imaging techniques to assess coronary artery bypass graft patency.

Graft patency verification is increasingly recognized as an important component of coronary artery bypass grafting. Intuitively, eliminating intraoperative graft failure should reduce cardiac mortality and morbidity in the short term and improve clinical outcome in the long term. Although conventional angiography remains the gold standard technique for assessing graft patency, it is rarely avai...

متن کامل

Unexpected hemodynamic deterioration and mitral regurgitation due to a tissue stabilizer during left anterior descending coronary anastomosis in off-pump coronary artery bypass graft surgery.

We have experienced three rare cases of hemodynamic deterioration and transient mitral regurgitation (MR) induced by a suction-type tissue stabilizer during the left internal thoracic artery (LITA)-to-LAD (left anterior descending) coronary artery anastomosis. Transesophageal echocardiogram (TEE) showed new or worsening MR during the placement of a tissue stabilizer. In all three cases, the pos...

متن کامل

The Right Gastroepiploic Artery Graft for Coronary Artery Bypass Grafting: A 30-Year Experience

Throughout its 30-year history, the right gastroepiploic artery (GEA) has been useful for in situ grafts in coronary artery bypass grafting (CABG). The early graft patency rate is high, and the late patency rate has improved by using the skeletonized GEA graft and proper target selection, which involves having a target coronary artery with a tight >90% stenosis. Total arterial revascularization...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiothoracic and vascular anesthesia

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2009