Tripling the detection view of high-frequency linear-array-based photoacoustic computed tomography by using two planar acoustic reflectors.

نویسندگان

  • Guo Li
  • Jun Xia
  • Kun Wang
  • Konstantin Maslov
  • Mark A Anastasio
  • Lihong V Wang
چکیده

BACKGROUND Linear-array-based photoacoustic computed tomography (PACT) suffers from a limited view. Circular scanning does increase the detection view angle but is time-consuming. Therefore, it is desirable to increase the detection view angle of linear-array-based PACT without sacrificing imaging speed. METHODS Two planar acoustic reflectors placed at 120 degrees to each other were added to a linear-array-based PACT system. Each reflector redirects originally undetectable photoacoustic waves back to the transducer array elements, and together they triple the original detection view angle of the PACT system. RESULTS Adding two reflectors increased the detection view angle from 80 to 240 degrees. As a comparison, a single-reflector PACT has a detection view angle of only 160 degrees. A leaf skeleton phantom with a rich vascular network was imaged with the double-reflector PACT, and most of its features were recovered. CONCLUSIONS The two acoustic reflectors triple the detection view angle of a linear-array-based PACT without compromising the original imaging speed. This nearly full-view detection capability produces higher-quality images than single-reflector PACT or conventional PACT without reflectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic imaging using acoustic reflectors to enhance planar arrays.

Planar sensor arrays have advantages when used for photoacoustic imaging: they do not require the imaging target to be enclosed, and they are easier to manufacture than curved arrays. However, planar arrays have a limited view of the acoustic field due to their finite size; therefore, not all of the acoustic waves emitted from a photoacoustic source can be recorded. This loss of data results in...

متن کامل

The use of acoustic reflectors to enlarge the effective area of planar sensor arrays

Planar sensor arrays have many advantages including ease of manufacture and low cost. However, when used for photoacoustic (PA) imaging, planar sensors have a limited view of the acoustic field, which means some of the waves from the PA source are not recorded. This results in artifacts in the reconstructed image of the PA source (the initial acoustic pressure distribution). In this paper, we d...

متن کامل

Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.

Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth ...

متن کامل

Improving limited-view photoacoustic tomography with an acoustic reflector.

The versatility and real-time imaging capability of commercial linear array transducers make them widely used in clinical ultrasound and photoacoustic imaging. However, they often suffer from limited detection view. For instance, acoustic waves traveling at a grazing angle to the transducer surface are difficult to detect. In this letter, we propose a simple and easy approach to ameliorate this...

متن کامل

Exact Photoacoustic Image Reconstruction using a Planar Sensor Array and Image Sources

Photoacoustic imaging with planar sensor arrays suffers from a finite aperture or limited view problem due to the fact that the sensor array is finite in size, whereas exact reconstruction algorithms require that it occupies the entire infinite plane. Here, acoustic reflectors are proposed as a means of reflecting the acoustic waves, that would otherwise not be measured, back onto the sensor, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Quantitative imaging in medicine and surgery

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2015