Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram: A Validation Approach
نویسندگان
چکیده
This paper provides a validation approach for a microwave Doppler Radar system used for heartbeat detection. The proposed system is tested at 16 GHz with several transmitted power, simultaneously with a pc-based electrocardiogram. Obtained results show accurate detection for the heartbeat signal in terms of heartbeat rate and heart rate variability.
منابع مشابه
Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram
This paper provides a validation approach for a microwave Doppler Radar system used for heartbeat detection. The proposed system is tested at 16 GHz with several transmitted power, simultaneously with a pc-based electrocardiogram. Obtained results show accurate detection for the heartbeat signal in terms of heartbeat rate and heart rate variability.
متن کاملPortable Non-contact Microwave Doppler Radar for Respiration and Heartbeat Sensing
Microwave L-band Doppler radar has been developed for pulmonic and cardiac activities investigation. Model of reflected signal spectra has been proposed, which is in qualitative agreement with both pulmonic and cardiac spectra. Distance sensitivity and penetration ability of the radar allows to quality it for typical indoor applications, as well as for life signal detection under avalanche.
متن کاملA novel technique for fetal heart rate estimation from Doppler ultrasound signal
BACKGROUND The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal,...
متن کاملSoftware Defined Doppler Radar as a Contactless Multipurpose Microwave Sensor for Vibrations Monitoring
A vibration sensor based on the use of a Software-Defined Radio (SDR) platform is adopted in this work to provide a contactless and multipurpose solution for low-cost real-time vibrations monitoring. In order to test the vibration detection ability of the proposed non-contact method, a 1 GHz Doppler radar sensor is simulated and successfully assessed on targets at various distances, with variou...
متن کاملUWB Mixer improvement with Regulated Voltage Source
This paper presents a design of an UWB downconversion integrated CMOS resistive ring mixer with Linear Voltage Regulator (LVR), to supply required biasing voltages for the mixer section. The designed mixer circuit has been optimized for using in heart rate extraction system with microwave Doppler radar at 2.4GHz frequency. This mixer needs 2 DC bias voltages equal to 0.5 and 1 volts for its bes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013