Continuous Monitoring of Essential Tremor Using a Portable System Based on Smartwatch
نویسندگان
چکیده
INTRODUCTION Essential tremor (ET) shows amplitude fluctuations throughout the day, presenting challenges in both clinical and treatment monitoring. Tremor severity is currently evaluated by validated rating scales, which only provide a timely and subjective assessment during a clinical visit. Motor sensors have shown favorable performances in quantifying tremor objectively. METHODS A new highly portable system was used to monitor tremor continuously during daily lives. It consists of a smartwatch with a triaxial accelerometer, a smartphone, and a remote server. An experiment was conducted involving eight ET patients. The average effective data collection time per patient was 26 (±6.05) hours. Fahn-Tolosa-Marin Tremor Rating Scale (FTMTRS) was adopted as the gold standard to classify tremor and to validate the performance of the system. Quantitative analysis of tremor severity on different time scales is validated. RESULTS Significant correlations were observed between neurologist's FTMTRS and patient's FTMTRS auto-assessment scores (r = 0.84; p = 0.009), between the device quantitative measures and the scores from the standardized assessments of neurologists (r = 0.80; p = 0.005) and patient's auto-evaluation (r = 0.97; p = 0.032), and between patient's FTMTRS auto-assessment scores day-to-day (r = 0.87; p < 0.001). A graphical representation of four patients with different degrees of tremor was presented, and a representative system is proposed to summarize the tremor scoring at different time scales. CONCLUSION This study demonstrates the feasibility of prolonged and continuous monitoring of tremor severity during daily activities by a highly portable non-restrictive system, a useful tool to analyze efficacy and effectiveness of treatment.
منابع مشابه
Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention
Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...
متن کاملObjective Quantification of Neuromotor Symptoms in Parkinson's Disease: Implementation of a Portable, Computerized Measurement Tool
Quantification of neuromotor symptoms with device-based measures provides a useful supplement to clinical evaluation. Research using the CATSYS has established its utility as a computerized measurement system to quantify neuromotor function. The primary objective of this study is to provide technical guidance on the use of the CATSYS in Parkinson's disease (PD). Forty-four patients with idiopat...
متن کاملTelemonitoring System of Neurological Signs in a Health Telematique Network
The paper presents a new, experimental, wireless tremor telemonitoring system composed of an optional variable number of portable devices integrating three-axis acceleration mini-sensors which are connected to very small dimensions acquisition systems with Wi-Fi transmission capabilities. The main advantages of the design system consist of the possibilities to monitor simultaneously many body p...
متن کاملQuantification of Parkinson Tremor Intensity Based On EMG Signal Analysis Using Fast Orthogonal Search Algorithm
The tremor injury is one of the common symptoms of Parkinson's disease. The patients suffering from Parkinson's disease have difficulty in controlling their movements owing to tremor. The intensity of the disease can be determined through specifying the range of intensity values of involuntary tremor in Parkinson patients. The level of disease in patients is determined through an empirical rang...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...