A sensitive high-temperature electrothermal atomic absorption analysis for Rb+ in erythrocytes and plasma of normal and hypertensive persons.

نویسندگان

  • K F Hallis
  • N A Boon
  • C M Perkins
  • J K Aronson
  • D G Grahame-Smith
چکیده

This method for determination of Rb+ in human plasma and erythrocytes by graphite-furnace atomic absorption spectrophotometry has a sensitivity of 29 nmol/L for plasma, 12 nmol/L for erythrocytes. The detection limit is 24 nmol/L for plasma, 4.8 nmol/L for erythrocytes. This assay is approximately 30-fold more sensitive than previously reported techniques involving atomic absorption spectrophotometry, enabling use of smaller samples. The rubidium signal is linear with concentration up to 1.2 mumol/L, and addition of other cations to the matrix produces only minor alterations in the Rb+ signal. We measured plasma and erythrocytic Rb+ concentrations in healthy subjects and in patients with untreated essential hypertension. In both, our values are similar to those previously reported for healthy individuals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy

At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...

متن کامل

Viscosity adaption for an automated micromethod of flame atomic absorption spectrometry, and intracellular trace-element analysis after pressure decomposition: zinc determination in plasma and erythrocytes.

We measured zinc in the plasma of 50 normal persons, and in erythrocytes of six, by an automated micromethod of atomic absorption spectrometry. Using a rotation viscometer, we measured the viscosity and flow behavior of plasma, undiluted and equi-volume diluted (with water), from 12 patients, and, for comparison, of two- to 20-fold dilutions of an 870 mL/L glycerol solution. Erythrocytes were w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 1985