Comparison of the presence-absence and membrane filter techniques for coliform detection in small, nonchlorinated water distribution systems.

نویسندگان

  • K Bancroft
  • E T Nelson
  • G W Childers
چکیده

The traditional membrane filter (American Public Health Association, Standard Methods for the Examination of Water and Wastewater, 16th ed., American Public Health Association, Washington, D.C., 1985) and presence-absence (P-A) (J. A. Clark, Can. J. Microbiol. 14:13-18, 1968) techniques for the detection of coliform bacteria were compared in a small nonchlorinated drinking water distribution system by using total positive samples and frequency-of-occurrence analyses. No significant differences (P less than 0.05) were found in detection of the presence of coliform bacteria or in changes in the frequency of occurrence with time. A reduction in P-A sample volume (to 50 ml) was not found to statistically affect the comparative results of traditional membrane filter and P-A tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of membrane filter, multiple-fermentation-tube, and presence-absence techniques for detecting total coliforms in small community water systems.

Methods for detecting total coliform bacteria in drinking water were compared using 1,483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a 10-tube fermentation tube (FT) technique, and the presence-absence (P-A) test. Each technique was evaluated using a 100-ml drinking water sample. O...

متن کامل

Fungi Occurrence Assessment in Drinking Water Distribution Systems and Its Relationship with Fecal Indicator Bacteria

Introduction: As recommended by World Health Organization, consumption of the fungal contaminated water does not cause to serious infection, but may lead to healthy or aesthetic problems. The aim of this research was to assess the occurrence of fungi in water and its relationship with fecal indicator bacteria. Materials and Methods: 110 water samples were collected from different location of w...

متن کامل

Application of ribotyping for differentiating aeromonads isolated from clinical and environmental sources.

We have investigated the usefulness of ribotyping for the differentiation of aeromonads isolated from five patients with gastroenteritis and from the source water, treatment plant, and distribution system of a small public water supply. Aeromonas hydrophila and Aeromonas caviae were isolated from fecal specimens preserved in Cary-Blair transport medium by using blood ampicillin agar or alkaline...

متن کامل

Comparison of Three Methods of Pour Plate (PP) ، Most Probable Number (MPN)and Membrane Filter (MF) for Detection of Escherichia coliin Well Water Samples in Tehran's Parks in 2010

Abstract Background and objectives: Water-born diseases are typically caused by pathogens transmitted by orofecal way. Because it is no practical and no economical and also it is time-consuming to find water-born pathogens in water reservoirs, the laboratory studies are performed on the basis of indicator microorganism. Escherichia coli is considered as the most important indicator bacterium fo...

متن کامل

A survey of heterotrophic bacteria and coliforms in the water of old and new distribution networks

Controlling the microbiological quality of water is important for its uses. Microbiological requirements of drinking water ensure the absence of coliforms, but may indicate the potential presence of other potentially pathogenic microorganisms and viruses of fecal origin. A total of 36 water samples, representing the drinking water of the whole city of Aradan, Semnan, Iran, were randomly collect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 1989