An Uncommon Intraoperative Implantable Cardiac Device Complication and Subsequent Troubleshooting
نویسندگان
چکیده
483 reconstruction with local tissue transfer. Intraoperatively, the surgeon noticed that the tumor was involving the pectoralis major muscle superiorly and was growing into the anterior and lateral pocket of the previous ICD generator location. This resection was undertaken carefully with the harmonic scalpel. One of the wires was intimately attached to the posterior aspect of the tumor embedded within the peritumoral fibrosis and was more posterior and lateral in location. Unknown to the surgeon, the LV wire’s insulation was damaged by the harmonic scalpel. The anesthesiologist immediately noticed a loss of the lead capture on the electrocardiogram with the patient having subsequent symptomatic bradycardia down to 40 beats/min. This acute change was immediately communicated to the surgeon. Emergent intraoperative cardiology consultation was obtained. ICD function was checked and determined that the LV wire was still functional. Silicone adhesive (Silastic® Medical Adhesive) was applied per Medtronic protocol over the damaged wire insulation to protect it. After the placement of the silicone adhesive, the ICD immediately started to recapture. The remainder of the surgical dissection was completed without further events, and the patient remained hemodynamically stable.
منابع مشابه
Anaesthetic consideration in patients with cardiac implantable electronic devices scheduled for surgery
With advances in cardiology and cardiothoracic surgery, several newer implantable cardiac devices have become common in the surgical population. Multichamber pacemakers, implanted cardiac defibrillators and ventricular assist devices are frequent in current day practice. Many of the newer implantable cardiac electronic devices are targeted at managing heart failure. While managing such patients...
متن کاملErosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملزندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیدهشناسی
Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...
متن کاملA Rare Cause of Cardiac Tamponade: Left Ventricular Pacemaker Malposition
The malpositioning of a pacemaker lead is an uncommon and under-reported complication of pacemaker/Automated Implantable Cardioverter-Defibrillator (AICD) placement. It can be associated with complications such as pericardial effusions and tamponade. We describe a case of an elderly woman who developed cardiac tamponade after inadvertent placement of a permanent pacing lead in the left ventricl...