Review of Alignment Activities at Jefferson Lab
نویسندگان
چکیده
The Thomas Jefferson National Accelerator Facility (Jefferson Lab) comprises a 6 GeV continuous electron beam accelerator (CEBAF) delivering beam to three experimental halls, and a kilowatt range tunable free electron laser (FEL), currently being upgraded to a 10 kW machine. The progression into steady state experimental runs at the facility has allowed the alignment group the opportunity to incorporate new developments into the alignment system. Two of these are discussed, together with some of the more unusual (e.g. gyrotheodolite survey) and the more routine surveys performed at the lab over the last three years.
منابع مشابه
Acams – Integrated Software for Accelerator
ACAMS (Accelerator Combined Alignment and Measurement System) is a software package that has been developed at Thomas Jefferson National Accelerator Facility (Jefferson Lab). ACAMS was developed to replace four MS-Dos based software programs. These programs operated independently and commonly used theodolite observations as the basis for data collection. The methodology used to collect the data...
متن کاملNeutron Transversity at Jefferson Lab
Nucleon transversity and single transverse spin asymmetries have been the recent focus of large efforts by both theorists and experimentalists. On-going and planned experiments from HERMES, COMPASS and RHIC are mostly on the proton or the deuteron. Presented here is a planned measurement of the neutron transversity and single target spin asymmetries at Jefferson Lab in Hall A using a transverse...
متن کاملPositrons at Jefferson Laboratory
We review the compelling case for establishing a capability to accelerate positrons at Jefferson Lab. The potential appplications range from the study of two-photon exchange and deeplyvirtual Compton scattering to exploiting the charge current weak interaction to probe the flavor structure of hadrons and nuclei. There are also fascinating ideas for using such a capability to discover new physic...
متن کاملHigh Average Current Effects in Energy Recovery Linacs*
Energy Recovery Linacs (ERLs) can be used as high efficiency driver accelerators to Free Electron Lasers, synchrotron radiation light sources and colliders. Energy recovery has been successfully demonstrated up to 5 mA of average current in the Jefferson Lab 1.7 kW IR FEL. Future designs call for much higher average currents of order 100 mA. A number of phenomena can potentially limit the perfo...
متن کاملPelvic Incidence in Patients with Hip Osteoarthritis
Background: Hip osteoarthritis (OA) is a major cause of pain and disability that results in considerable social and medical costs. Mechanics such as posture, alignment and orientation of the hips and the spinal column and the relationship between these factors have been implicated in the development of both hip and spine pathologies. This study aims to test the hypothesis if pelvic incidenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003