Three order increase in scanning speed of space charge-controlled KTN deflector by eliminating electric field induced phase transition in nanodisordered KTN
نویسندگان
چکیده
In this paper, we report a three orders-of-magnitude increase in the speed of a space-charge-controlled KTN beam deflector achieved by eliminating the electric field-induced phase transition (EFIPT) in a nanodisordered KTN crystal. Previously, to maximize the electro-optic effect, a KTN beam deflector was operated at a temperature slightly above the Curie temperature. The electric field could cause the KTN to undergo a phase transition from the paraelectric phase to the ferroelectric phase at this temperature, which causes the deflector to operate in the linear electro-optic regime. Since the deflection angle of the deflector is proportional to the space charge distribution but not the magnitude of the applied electric field, the scanning speed of the beam deflector is limited by the electron mobility within the KTN crystal. To overcome this speed limitation caused by the EFIPT, we propose to operate the deflector at a temperature above the critical end point. This results in a significant increase in the scanning speed from the microsecond to nanosecond regime, which represents a major technological advance in the field of fast speed beam scanners. This can be highly beneficial for many applications including high-speed imaging, broadband optical communications, and ultrafast laser display and printing.
منابع مشابه
High-Speed Optical Coherence Tomography System Using a 200-kHz Swept Light Source with a KTN Deflector
We demonstrate a high-speed swept-source optical coherence tomography (SS-OCT) system, which is based on a highspeed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light source is an external-cavity laser tuned by a KTN electro-optic deflector, which exhibits a very fast response and large deflection. The scanning wavelength range is almost 80 nm up to...
متن کاملSome quantitative relationships between leaf area index and canopy nitrogen content and distribution.
In a previous study (Yin et al. 2000. Annals of Botany 85: 579-585), a generic logarithmic equation for leaf area index (L) in relation to canopy nitrogen content (N) was developed: L=(1/ktn)1n(1+ktnN/nb). The equation has two parameters: the minimum leaf nitrogen required to support photosynthesis (nb), and the leaf nitrogen extinction coefficient (ktn). Relative to nb, there is less informati...
متن کاملPotentiation of a topoisomerase I inhibitor, karenitecin, by the histone deacetylase inhibitor valproic acid in melanoma: translational and phase I/II clinical trial.
PURPOSE The novel topoisomerase I inhibitor karenitecin (KTN) shows activity against melanoma. We examined whether histone deacetylase inhibition could potentiate the DNA strand cleavage, cytotoxicity as well as the clinical toxicity, and efficacy of KTN in melanoma. EXPERIMENTAL DESIGN Apoptosis, COMET, and xenograft experiments were carried out as described previously. A phase I/II trial of...
متن کاملKTa0.6Nb0.4O3 ferroelectric thin film behavior at microwave frequencies for tunable applications.
In this study about the relationships between structural and microwave electrical properties of KTa(1-x)NbxO3 (KTN) ferroelectric materials, a KTN thin film was deposited on different substrates to investigate how KTN growth affects the microwave behavior. Interdigital capacitors and stubs were made on these films through a simple engraving process. Microwave measurements under a static electri...
متن کاملStudy by simulation the influence of temperature on the formation of space charge in the dielectric multilayer Under DC Electric stress
Multidielectric polyethylene is a material that is generally employed as insulation for the HVDC isolations. In this paper, the influence of temperature on space charge dynamics has been studied, low-density polyethylene (LDPE) and Fluorinated Ethylene Propylene (FEP) sandwiched between two electrodes were subjected to voltage application of 5kV (14.3 kV/mm) for extended duration of time ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -