Comparison of cross-sectional HIV incidence assay results from dried blood spots and plasma

نویسندگان

  • Katherine E Schlusser
  • Christopher Pilcher
  • Esper G Kallas
  • Breno R Santos
  • Steven G Deeks
  • Shelley Facente
  • Sheila M Keating
  • Michael P Busch
  • Gary Murphy
  • Alex Welte
  • Thomas Quinn
  • Susan H Eshleman
  • Oliver Laeyendecker
چکیده

BACKGROUND Assays have been developed for cross-sectional HIV incidence estimation using plasma samples. Large scale surveillance programs are planned using dried blood spot (DBS) specimens for incidence assessment. However, limited information exists on the performance of HIV cross-sectional incidence assays using DBS. METHODS The assays evaluated were: Maxim HIV-1 Limiting Antigen Avidity EIA (LAg-Avidity), Sedia HIV-1 BED-Capture EIA (BED-CEIA), and CDC modified BioRad HIV-1/2 Plus O Avidity-based Assay (CDC-BioRad Avidity) using pre-determined cutoff values. 100 matched HIV-1 positive plasma and DBS samples, with known duration of infection, from the Consortium for the Evaluation and Performance of HIV Incidence Assays repository were tested. All assays were run in duplicate. To examine the degree of variability within and between results for each sample type, both categorical and continuous results were analyzed. Associations were assessed with Bland Altman, R2 values and Cohen's kappa coefficient (ĸ). RESULTS Intra-assay variability using the same sample type was similar for all assays (R2 0.96 to 1.00). The R2 values comparing DBS and plasma results for LAg-Avidity, BED-CEIA, and CDC-BioRad Avidity were 0.96, 0.94, and 0.84, respectively. The concordance and ĸ values between DBS and plasma for all three assays were >87% and >0.64, respectively. The Bland-Altman analysis showed significant differences between plasma and DBS samples. For all three assays, a higher number of samples were classified as recent infections using DBS samples. CONCLUSIONS DBS and plasma sample results were highly correlated. However, when compared to plasma, each assay performed somewhat differently in DBS at the lower and higher ends of the dynamic range. DBS samples were more likely to be classified as recently infected by all three assays, which may lead to overestimation of incidence in surveys using performance criteria derived for plasma samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Dried Blood Spots with a Multiplex Assay for Measuring Recent HIV-1 Infection

Laboratory-based HIV tests for recent infection (TRIs), which primarily measure a specific serological biomarker(s) that distinguishes recent from long-term HIV infection, have facilitated the estimation of population-based incidence. Dried blood spots (DBS) on filter paper are an attractive sample source for HIV surveillance, given the simplified and cost-effective methods of specimen collecti...

متن کامل

Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay.

BACKGROUND The use of simplified methods for viral load determination could greatly increase access to treatment monitoring of HIV patients in resource-limited countries. OBJECTIVE The aim of the present study was to optimize and evaluate the performance of the Roche COBAS Taqman assay in HIV-RNA quantification from dried blood spots (DBS) and dried plasma spots (DPS). STUDY DESIGN EDTA blo...

متن کامل

A cost-effective particle agglutination assay to detect viral antibodies in dried blood spots--a simple solution to HIV and HCV screening.

OBJECTIVES To conduct a serological survey of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) in Gabon and Ga-Rankuwa, South Africa. A secondary objective was to test a novel, simple, inexpensive agglutination assay for anti-HIV IgG and anti-HCV IgG from blood samples stored as spots dried onto filter paper. DESIGN Blood from heel pricks was dried onto filter paper and stored. ...

متن کامل

Use of dried spots of whole blood, plasma, and mother's milk collected on filter paper for measurement of human immunodeficiency virus type 1 burden.

We studied the use of dried spots of bodily fluids (plasma, whole blood, and mother's milk) on filter paper as a means of sample collection and storage for human immunodeficiency virus type 1 (HIV-1) viral load testing under stringent field conditions. Plasma placed directly in lysis buffer, which is customarily used for viral load assays, was used for comparison in all our experiments. Utilizi...

متن کامل

DrieD BlooD SpotS

The multi-region hybridization assay (MHAbce) for genotyping HIV-1 subtypes B, C and circulating recombinant form (CRF01_AE) was evaluated on paired plasma and dried blood spots (DBS) collected from 68 HIV-1 infected individuals in Thailand. CRF01_AE was the predominant subtype identified using plasma samples (51/62) and DBS (24/27). There was no discordance in subtype designations between plas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017