Electroporation induced by internal defibrillation shock with and without recovery in intact rabbit hearts.
نویسندگان
چکیده
Defibrillation shocks from implantable cardioverter defibrillators can be lifesaving but can also damage cardiac tissues via electroporation. This study characterizes the spatial distribution and extent of defibrillation shock-induced electroporation with and without a 45-min postshock period for cell membranes to recover. Langendorff-perfused rabbit hearts (n = 31) with and without a chronic left ventricular (LV) myocardial infarction (MI) were studied. Mean defibrillation threshold (DFT) was determined to be 161.4 ± 17.1 V and 1.65 ± 0.44 J in MI hearts for internally delivered 8-ms monophasic truncated exponential (MTE) shocks during sustained ventricular fibrillation (>20 s, SVF). A single 300-V MTE shock (twice determined DFT voltage) was used to terminate SVF. Shock-induced electroporation was assessed by propidium iodide (PI) uptake. Ventricular PI staining was quantified by fluorescent imaging. Histological analysis was performed using Masson's Trichrome staining. Results showed PI staining concentrated near the shock electrode in all hearts. Without recovery, PI staining was similar between normal and MI groups around the shock electrode and over the whole ventricles. However, MI hearts had greater total PI uptake in anterior (P < 0.01) and posterior (P < 0.01) LV epicardial regions. Postrecovery, PI staining was reduced substantially, but residual staining remained significant with similar spacial distributions. PI staining under SVF was similar to previously studied paced hearts. In conclusion, electroporation was spatially correlated with the active region of the shock electrode. Additional electroporation occurred in the LV epicardium of MI hearts, in the infarct border zone. Recovery of membrane integrity postelectroporation is likely a prolonged process. Short periods of SVF did not affect electroporation injury.
منابع مشابه
Mechanisms of enhanced shock-induced arrhythmogenesis in the rabbit heart with healed myocardial infarction.
Shock-induced vulnerability and defibrillation have been mostly studied in structurally normal hearts. However, defibrillation therapy is normally applied to patients with diseased hearts, frequently those with prior myocardial infarction (MI). Shock-induced vulnerability and defibrillation have not been well studied under this condition. We sought to examine the mechanisms of shock-induced arr...
متن کاملThe role of electroporation in defibrillation.
Electric shock is the only effective therapy against ventricular fibrillation. However, shocks are also known to cause electroporation of cell membranes. We sought to determine the impact of electroporation on ventricular conduction and defibrillation. We optically mapped electrical activity in coronary-perfused rabbit hearts during electric shocks (50 to 500 V). Electroporation was evident fro...
متن کاملVirtual electrode-induced reexcitation: A mechanism of defibrillation.
Mechanisms of defibrillation remain poorly understood. Defibrillation success depends on the elimination of fibrillation without shock-induced arrhythmogenesis. We optically mapped selected epicardial regions of rabbit hearts (n=20) during shocks applied with the use of implantable defibrillator electrodes during the refractory period. Monophasic shocks resulted in virtual electrode polarizatio...
متن کاملProlong the Duration of Depolarization and the Refractory Period
The present data were obtained using the technique of optical recording with the voltagesensitive dye WW781. This technique, unlike electrical methods, was able to provide uninterrupted recordings free of artifacts during defibrillation shocks. Optical recordings were made from sites on the ventricular epicardium of perfused rabbit hearts during electrical pacing. Continuous recordings of the e...
متن کاملOptical recordings in the rabbit heart show that defibrillation strength shocks prolong the duration of depolarization and the refractory period.
The present data were obtained using the technique of optical recording with the voltage-sensitive dye WW781. This technique, unlike electrical methods, was able to provide uninterrupted recordings free of artifacts during defibrillation shocks. Optical recordings were made from sites on the ventricular epicardium of perfused rabbit hearts during electrical pacing. Continuous recordings of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 303 4 شماره
صفحات -