Influence of the rate of contrast change on the quality of contrast sensitivity assessment: a comparison of three psychophysical methods.
نویسندگان
چکیده
Criterion-free forced-choice procedures for measuring contrast sensitivity with a cathode ray tube (CRT) have low within-subject, intersubject, and test-retest variabilities, but a long test time compared with psychophysical methods that rely on the subject's criterion to determine threshold. Test time and variability of criterion-dependent methods depend on the rate at which the contrast changes on the CRT display. This study compared two criterion-dependent psychophysical methods for measuring contrast sensitivity (the method of increasing contrast and the von Békésy tracking method) with a criterion-free two-alternative forced-choice procedure. A range of rates of contrast change was studied: 0.1, 0.3, 0.5, 0.7 and 1.0 log unit s-1. Contrast sensitivity, within-subject variability, intersubject variability, test-retest variability, and test time of the three methods were compared. The 2-AFC procedure performed best with regard to within-subject, intersubject, and test-retest variabilities. A time-efficient alternative was the von Békésy tracking method at rates between 0.1 and 0.5 log unit s-1.
منابع مشابه
The Evaluation of Yellow vs. Blue Color Contrast Sensitivity pre and Post LASIK
Introduction: contrast sensitivity is one of the most important psychophysical tests that may be used for the evaluation of refractive state of eye and retinal image quality. Yellow vs. blue color contrast sensitivity may be more suitable in this regard. Materials and Methods: thirty myopic eyes were considered in this study. Yellow vs. blue color contrast sensitivity was evaluated under the sa...
متن کاملAssessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملA study of densitometry comparison among three radiographic processing solutions
ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...