Supraclavicular brachial plexus block using a nerve stimulator and an insulated needle.
نویسندگان
چکیده
A technique employing a nerve stimulator and an insulated needle was used for supraclavicular brachial plexus block in 71 patients using 0.5% plain bupivacaine 15-20 ml. The mean minimal stimulating current to produce paraesthesia was 0.09 mA. The plexus was identified at a mean depth of 27 mm below the skin. The block was successful in 98% of patients when the stimulation was felt in the index, middle or ring finger, but was often incomplete when felt in the thumb or little finger.
منابع مشابه
The technique comparison of brachial plexus blocks by ultrasound guided with blocks by nerve stimulator guided.
OBJECTIVE Brachial plexus perineural blocks provide specific analgesia for upper limb surgery. We present our experience with ultrasound-guided supraclavicular brachial plexus perineural blocks for distal upper limb surgery. Although single-injection ultrasound-guided supraclavicular blocks have been reported, little is known about the advantages using this approach compared with nerve stimulat...
متن کاملA Comparative Study between Anatomical Landmark and Nerve Stimulator Guided Supraclavicular Brachial Plexus Block for Neurovascular Variations in Topographic Anatomy of Brachial Plexus
A comparative study between anatomical landmark and nerve stimulator guided supraclavicular brachial plexus block for neurovascular variations in topographic anatomy of brachial plexus. In the backdrop of our country, nerve stimulator is still not available in many centres and many anesthetists do not yet have the proper expertise and experience in giving nerve stimulator guided brachial plexus...
متن کاملUltrasound-guided Brachial Plexus Block at the Supraclavicular Level: A New Parasagittal Approach
The study evaluates a new approach to ultrasound-guided supraclavicular brachial plexus block using a supraclavicular parasagittal approach. Sixty outpatients scheduled for hand surgery were given brachial plexus block utilising the new approach. Time taken for block procedure was short and onset time for sensory block was rapid, using a low volume of local anaesthetic agent, with the volume de...
متن کاملبلوک شبکه عصبی براکیال با هدایت اولتراسوند: بررسی 30 مورد
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...
متن کاملBrachial plexus examination and localization using ultrasound and electrical stimulation: a volunteer study.
BACKGROUND Current techniques of brachial plexus block are "blind," and nerve localization can be frustrating and time consuming. Previous studies on ultrasound-assisted brachial plexus blocks are mostly performed with scanning probes of 10 MHz or less. The authors tested the usefulness of a state-of-the-art, high-resolution ultrasound probe (up to 12 MHz) in identifying the brachial plexus in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 52 4 شماره
صفحات -
تاریخ انتشار 1980