Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction.

نویسندگان

  • Christoph Forman
  • Davide Piccini
  • Robert Grimm
  • Jana Hutter
  • Joachim Hornegger
  • Michael O Zenge
چکیده

PURPOSE To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free-breathing 3D whole-heart coronary mra using respiratory motion-resolved sparse reconstruction

Background Navigator gating is commonly used to minimize respiratory motion in free-breathing whole-heart coronary MRA [1]. However, lengthy and unpredictable acquisition times remain a drawback. Respiratory self-navigation (SN) [2-3], conversely, enables 100% scan efficiency, but performs motion correction over a broad range of respiratory displacements, which can result in image artifacts. He...

متن کامل

Free-Breathing Whole-Heart Coronary MRA: Motion Compensation Integrated into 3D Cartesian Compressed Sensing Reconstruction

Respiratory motion remains a major challenge for whole-heart coronary magnetic resonance angiography (CMRA). Recently, iterative reconstruction has been augmented with non-rigid motion compensation to correct for the effects of respiratory motion. The major challenge of this approach is the estimation of dense deformation fields. In this work, the application of such a motion-compensated recons...

متن کامل

3D projection reconstruction based respiratory motion correction technique for free-breathing coronary MRA

INTRODUCTION: Respiratory motion is one of the major challenges for coronary MRA. Current navigator based free-breathing techniques measure the position of the diaphragm and use a fixed correlation factor to estimate the position of the heart. Such techniques suffer from errors due to the indirect estimation of heart position and are plagued by low scan efficiencies (typically between 30 and 50...

متن کامل

ECG and navigator-free 4D whole-heart coronary MRA

Background Cardiac and respiratory motion artifacts are major challenges to whole-heart coronary MRA. The conventional motion suppression strategies often involve prospective gating based on motion surrogates, e.g. ECG and navigator, which complicates scan setup and prolongs scan time significantly. To address these limitations, an ECG and navigator-free 4D whole-heart coronary MRA technique wa...

متن کامل

Self-guided retrospective motion correction (SEGMO) for free-breathing whole-heart coronary MRA with 100% acquisition efficiency

Background Free-breathing whole heart coronary MRA uses diaphragm navigator to gate data acquisition, which suffers from the need for time-consuming and exquisite positioning, prolonged scan time due to low gating efficiency, and inaccuracy in motion detection. In this work, a respiratory motion correction scheme is proposed with an affine motion model for accurate estimation of respiratory mot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 2015