Monitoring success of remediation: seven case studies of moisture and mold damaged buildings.

نویسندگان

  • Ulla Haverinen-Shaughnessy
  • Anne Hyvärinen
  • Tuula Putus
  • Aino Nevalainen
چکیده

Based on seven case studies of buildings that underwent different degrees of moisture and mold damage remediation, we aimed to develop methodology for assessment of the success of the remediation process. Methods used in gauging the success included technical monitoring of performance of building structures and heating, ventilation and air conditioning (HVAC) systems, microbial monitoring of indoor air quality (IAQ), and health effects studies of building occupants. The assessment was based on measurable change in the situations before and after remediation. Based on technical monitoring, remediation was successful in three cases, with partial improvement noted in three cases, whereas no remediation was conducted in one case. Based on microbial monitoring, improvement was detected in one, partial improvement in two and no improvement in two cases, whereas no follow-up was conducted in two cases. Health effect studies (mainly self-reported health status) showed improvement in one case, partial improvement in two cases, and no improvement in two cases, whereas no follow-up was conducted in one case, and in one case, follow-up failed due to low response rate. The results illustrate that it is possible to monitor the effects of remediation using various metrics. However, in some cases, no improvement could be observed in IAQ or occupant health, even if the remediation was considered technically successful, i.e. the remediation was fully completed as recommended. This could be due to many reasons, including: 1) all damage may not have been addressed adequately; 2) IAQ or health may not have been perceived improved regardless of remediation; and/or 3) the methods used may not have been sensitive/specific enough to detect such improvement within the 6-12 months follow-up periods after completion of the remediation. There is a need to further develop tools for monitoring and assessment of the success of moisture damage remediation in buildings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings: the effect on biological activity and microbial flora.

Many building-related health problems coincide with moisture damage and mold growth within a building. Their elimination is assumed to improve indoor air quality. The aim of this study was to follow the success of remediation in two individual buildings by analyzing the microbial flora and immunotoxicological activity of filter samples. We compare results from samples collected from indoor air ...

متن کامل

Association of Streptomyces community composition determined by PCR-denaturing gradient gel electrophoresis with indoor mold status.

Both Streptomyces species and mold species have previously been isolated from moisture-damaged building materials; however, an association between these two groups of microorganisms in indoor environments is not clear. In this study, we used a culture-independent method, PCR-denaturing gradient gel electrophoresis (PCR-DGGE), to investigate the composition of the Streptomyces community in house...

متن کامل

Amoebae and other protozoa in material samples from moisture-damaged buildings.

Mold growth in buildings has been shown to be associated with adverse health effects. The fungal and bacterial growth on moistened building materials has been studied, but little attention has been paid to the other organisms spawning in the damaged materials. We examined moist building materials for protozoa, concentrating on amoebae. Material samples (n = 124) from moisture-damaged buildings ...

متن کامل

Effects of Moisture Damage Repair on Microbial Exposure and Health Effects in Schools

This intervention study was designed to show the effects of the renovation of moisture and mold damaged school building on the schoolchildren’s health and exposure. Microbial sampling from indoor air of the school and a health questionnaire study were performed before and after renovation. The results were compared to those from non-damaged reference school. The effect of a thorough renovation ...

متن کامل

Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.

Damp buildings often have a moldy smell or obvious mold growth; some molds are human pathogens. This has caused concern regarding health effects of moldy indoor environments and has resulted in many studies of moisture- and mold-damaged buildings. Recently, there have been reports of severe illness as a result of indoor mold exposure, particularly due to Stachybotrys chartarum. While many autho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 399 1-3  شماره 

صفحات  -

تاریخ انتشار 2008