Position sensitivity of the first SmartPET HPGe detector

نویسندگان

  • R. J. Cooper
  • I. Lazarus
  • J. Simpson
  • A. Berry
  • T. Beveridge
  • J. Gillam
  • R. A. Lewis
چکیده

In this paper we discuss the Smart Positron Emission Tomography (PET) imaging system being developed by the University of Liverpool in conjunction with CCLRC Daresbury Laboratory. We describe the motivation for the development of a semiconductorbased PET system and the advantages it will offer over current tomographs. Details of the detectors and associated electronics are discussed and results of high precision scans are presented. Analysis of this scan data has facilitated full characterization of the detector response function and calibration of the three-dimensional position sensitivity. This work presents the analysis of the depth sensitivity of the detector. r 2006 Elsevier B.V. All rights reserved. PACS: 07.85. m; 29.40.Gx; 87.62.+n

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Reconstruction of a Radiation Point Source’s Radial Location Using Goodness-of-Fit Test on Spectra Obtained from an HPGe Detector

High purity germanium (HPGe) detectors are ubiquitous in nuclear physics experiments and are also used in numerous low radioactive background detectors. The effect of the position of Co and Cs point sources on the shape of spectra were studied with Monte Carlo and HPGe detector measurements. We briefly confirm previous work on the position dependence of relative heights of peaks. Spectra taken ...

متن کامل

تعیین لایه مرده‎ و بازده قله تمام - انرژی آشکارساز HPGe بااستفاده از کد MCNP و نتایج تجربی

One important factor in using an High Purity Germanium (HPGe) detector is its efficiency that highly depends on the geometry and absorption factors, so that when the configuration of source-detector geometry is changed, the detector efficiency must be re-measured. The best way of determining the efficiency of a detector is measuring the efficiency of standard sources. But considering the fact t...

متن کامل

Efficiency determination of HPGe detector by simulation and experimental methods for solid volume source

Analyzes of environmental samples regarding their radioactivity is of important concern for health purposes. We need standard sources to determine radioactive components and their activities. These sources are usually produced regarding type of the sample. One of the fundamental and precise tools to recognize radioactive materials and their activities is HPGe detector. To reach this goal, the d...

متن کامل

ارزیابی مکان آشکارساز نقطه‌ای مجازی در آشکارساز HPGe تخت برای محدوده انرژی k‏eV661-13با استفاده از چشمه‌های فیلتر کاغذی

One of the most important instruments in gamma ray spectroscopy is HPGe detector. Concept of virtual point detector was considered for Ge(Li) detector. On the basis of this concept, there is a point inside a Ge detector that can be regarded as a fictitious point detector hosting all the interactions. If there is really a point whose response can be considered similar to that of the whole real b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006