The Concept of Short-circuit Power and the Assessment of the Flicker Emission Level

نویسندگان

  • M. Couvreur
  • E. De Jaeger
  • P. Goossens
  • A. Robert
چکیده

The paper starts with an overview of different concepts of short-circuit power: the IEC standard, the effective and the apparent short-circuit power. The short-circuit power is a key concept in characterising the ability of a power system to feed fluctuating loads without excessive flicker levels. Its apparent value (from measurements) is generally higher than its standard value (from calculations in standard conditions).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارتقای کیفیت توان و بهبود فرآیند کنترل کوره قوس الکتریکی با استفاده از UPQC

Electrical Arc Furnace (EAF) is large, nonlinear and time-varying load that affects power quality of the power system by producing many problems such as harmonics, flicker, current unbalance and low power factor. This paper proposes a modified Unified Power Quality Conditioner (UPQC) to reduce power quality problems of EAF and enhance its controllability. Harmonic reduction, power quality impro...

متن کامل

Determination of Optimal Allocation and Penetration Level of Distributed Energy Resources Considering Short Circuit Currents

The integration of Distributed Energy Resources (DER) in the distribution network has plenty of advantages if their allocation and Penetration Level (PL) are done appropriately. Hence, the challenge of finding the best allocation and PL of DERs in large distribution networks is an important but intricate problem. This paper proposes a novel methodology to simultaneously determine the optimal lo...

متن کامل

Decreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points

Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...

متن کامل

Power System Transient Stability Analysis Based on the Development and Evaluation Methods

A novel method to compute the stability region in power system transient stability analysis is presented. This method is based on the set analysis. The key to this method is to construct the Hamilton-Jacobi-Isaacs (HJI) partial differential equation (PDE) of a nonlinear system, using which we can compute the backward reachable set by applying the level set methods. The backward reachable set of...

متن کامل

Optimal Placement and Sizing of Fault Current Limiter in a Real Network: a Case Study (TECHNICAL NOTE)

In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000