Using global PSF properties to probe the WFC 3 UVIS

نویسندگان

  • Massimo Stiavelli
  • Christopher Hanley
چکیده

This ISR briefly reviews how the WFC3 UVIS channel focus and alignment impact the PSF. The aim is to verify whether we can identify any simple PSF measurement that would allows to monitor these quantities. We find that the centering of the PSF within a pixel is a crucial parameter that needs to be calibrated or corrected for and that PSF sharpness is the most promising parameter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WFC 3 UVIS PSF Evaluation in Thermal - Vacuum Test # 3

We have assessed the image quality of the WFC3 UVIS channel in a flight-like thermalvacuum environment, and with its flight detector installed. Point source measurements at 16 field positions and four wavelengths indicate excellent imaging performance for the UVIS channel. Encircled energies readily meet expectations over the field, with CASTLE stimulus illumination. Models including the mid-fr...

متن کامل

WFC 3 2008 - 32 WFC 3 Optical Alignment Characterization in Thermal - Vacuum Test # 3

We have performed an assessment of the optical alignment of the WFC3 instrument in its final flight configuration, including the UVIS-1’ and IR-4 detectors, during the 3 thermal-vac test in March 2008. Both detectors are found to be aligned to well within tolerance in all degrees of freedom. The corrector settings, after adjustment to optimize image quality, are within the budgeted range for gr...

متن کامل

Preliminary WFC3 UVIS PSF Evaluation

We have made an initial assessment of the image quality of the WFC3 UVIS channel with its flight detector installed. Point source measurements at four field positions and four wavelengths indicate excellent imaging performance for the UVIS channel, with CEI encircled energy specifications readily achieved.

متن کامل

WFC 3 SMOV Program 11427 : UVIS Channel Shutter Shading

A series of internal flat field images and standard star observations were used to quantify the behavior of the UVIS channel shutter mechanism. Photometry of the stars and flat field analysis show that the UVIS shutter functionality in SMOV is comparable to that in ground testing. Shutter shading causes a variation in exposure time across the detector of no more than 0.0009 seconds. On-orbit ra...

متن کامل

PSFs, Photometry, and Astrometry for the ACS/WFC

We develop and present effective PSFs for the F606W filter in the WFC, and then for five other filters. After briefly reviewing the concept of the effective PSF, we show that the WFC PSF varies with position in the detector. We represent the PSF by a 9×10 array of fiducial PSFs, between which a tailor-made PSF is to be interpolated for each star. Fitting these PSFs to star images gives photomet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002