Computer-based periaxial rotation measurement for aligning fractured femur fragments
نویسندگان
چکیده
A new computer-based method for measuring periaxial rotation of healthy and fractured femurs from preoperative CT during closed femoral fracture reduction surgery is described. The method provides a comparative quantitative measure to align the distal and proximal femur fragments based on periaxial rotation. The periaxial rotation is defined in terms of patient-specific bone features. An algorithm for automatically extracting these features from the CT based on this definition has been developed. The algorithm extracts the condyle landmarks and neck axis of the healthy bone, determines its periaxial rotation, and extrapolates this data, assuming mirror symmetry between the healthy and fractured bones, to measure periaxial rotation between the fractured fragments. Unlike existing techniques, the method requires minimal user intervention. In a feasibility study, the method was applied to five dry femurs and one patient data set, and simulated a reduction based on the periaxial measurements with satisfactory results. The experiments showed the measured angle on the fractured femur to be within 1-4.5 degrees of that of the healthy bone.
منابع مشابه
Computer-Based Periaxial Rotation Measurement for Aligning Fractured Femur Fragments from CT: a Feasibility Study
A new computer-based method for periaxial rotation measurement of healthy and fractured fe murs during closed femoral fracture reduction surgery from preoperative CT is described. The method provides a comparative quantitative measure to align the distal and proximal femur fragments based on periaxial rotation. The periaxial rotation is define d in terms of patient-specific bone features. An al...
متن کامل3D atlas-based registration can calculate malalignment of femoral shaft fractures in six degrees of freedom
OBJECTIVE This study presents and evaluates a semi-automated algorithm for quantifying malalignment in complex femoral shaft fractures from a single intraoperative cone-beam CT (CBCT) image of the fractured limb. METHODS CBCT images were acquired of complex comminuted diaphyseal fractures created in 9 cadaveric femora (27 cases). Scans were segmented using intensity-based thresholding, yieldi...
متن کاملIntraoperative cone-beam CT for correction of periaxial malrotation of the femoral shaft: a surface-matching approach.
Limb length, alignment and rotation can be difficult to determine in femoral shaft fractures. Shaft axis rotation is particularly difficult to assess intraoperatively. Femoral malpositioning can cause deformity, pain and secondary degenerative joint damage. The aim of this study is to develop an intraoperative method based on cone-beam computed tomography (CBCT) to guide alignment of femoral sh...
متن کاملEffect of distal interlock fixation in stable intertrochanteric fractures.
The objective of this study was to evaluate the torsion stiffness of locked and unlocked distal fixation of long cephalomedullary nail constructs, in both a fresh fracture and healed, stable intertrochanteric fracture model. Samples were tested in both internal and external rotation (0±3 Nm) for a duration of 10 cycles. Each femur was tested without instrumentation (intact femur), with instrume...
متن کاملComputed Tomographic measurement of distal femor rotation in Iranian population
Background: Proper rotation of components in total knee arthroplasty (TKA) will largely affect the postoperative outcome. Ethnical variation may affect rotational profile. We aimed to evaluate distal femur rotation in Iranian population using transepicondylar axes. Methods : From a total of 450 knee CT scans and via consecutive sampling, 150 qualified subjects with normal lower extremities ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computer aided surgery : official journal of the International Society for Computer Aided Surgery
دوره 7 6 شماره
صفحات -
تاریخ انتشار 2001