Two whole-blood multi-analyte analyzers evaluated.

نویسندگان

  • M Fleisher
  • M Gladstone
  • D Crystal
  • M K Schwartz
چکیده

We evaluated two multi-analyte analyzers, the NOVA Stat Profile 1 (SP 1) and the NOVA Stat Profile 5 (SP 5). The SP 1 measures pH, pCO2, pO2, sodium, potassium, ionized calcium, and hematocrit in heparinized whole blood; the SP 5 determines all these analytes, plus chloride (not evaluated because it was unavailable at the time this study was initiated) and glucose. Interassay precision for pH, pCO2, pO2, sodium, potassium, ionized calcium, and hematocrit (all on the SP 1) and glucose (on the SP 5) was excellent, the respective CVs (%) being: less than 0.006, 2.1, less than or equal to 3.0, less than or equal to 0.5, less than or equal to 1.7, less than or equal to 2.1, less than or equal to 3.9, and less than or equal to 1.2. Correlation with results obtained with Corning's Model 178, NOVA Biomedical's Model 6, Beckman's Astra 8, and Roche's Cobas-Bio was also excellent (r greater than 0.975 for all analytes, r for hematocrit 0.865). Temperature-stability studies on whole-blood specimens maintained at 1 degree C indicated that results for all measured analytes were essentially uncharged for at least 2 h, except for potassium, which increased by 13% in 2 h. At 22 degrees C, values for pH, pCO2, pO2, and glucose changed significantly within 2 h. Advantages of the NOVA Stat Profile series include decreased specimen requirements (250 microL), analysis time (72-90 s), turnaround time (about 4.5 min), and overall cost of operation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of multi-channel analyzers by use of linearly-related survey specimens.

Sets of specimens having quantitative linear inter-relationships for 25 analytes were prepared and used in a small survey of results with multi-channel analyzers. Instrument calibration was evaluated by linear regression analysis of the analytical results, with calculation of the x- and y-intercepts and slopes. The average intercepts and slopes agreed quite well with those expected on the basis...

متن کامل

Fast Reading of C-Reactive Protein in Whole Blood in Hematology Analyzers

A new homogeneous immunoassay of whole blood C-reactive protein based on the use of magnetic fieldassisted agglutination of polyclonal anti-CRP coated superparamagnetic particles is described. These particles self-organize into linear chains under an appropriate magnetic field which considerably increase the colliding frequency and thus, the probability to form links between ligand and receptor...

متن کامل

Optimized kinetic glutamate dehydrogenase assay adapted to the Cobas Bio centrifugal analyzer.

Details of the Vision System operation have been previously described (2). Each test pack is provided with a code for investigation and intended for single use. It can accommodate 40-120 L of whole blood, plasma, or serum. Clinical chemistry tests performed on the Vision System are optimized and based on the known-solution chemistry methods (3-5). We evaluated the precision and accuracy of Betw...

متن کامل

Blood Gas and Critical Care Analyte Analysis

point of care (POC) in critical care areas such as the emergency department, neonatal and adult medical intensive care units, surgical intensive care units, and the operating room.2 The collection and analysis by portable or standard blood gas machines at or near the point of care minimizes the time needed to obtain and report laboratory values, which facilitates timely evaluation of results an...

متن کامل

Inter-instrument comparison of blood gas analyzers and assessment of tonometry using fresh heparinized whole human blood.

Because of limitations associated with commercial blood gas quality controls and tonometry of stored blood, fresh heparinized blood was used to compare PO2 and PCO2 performance of ten blood gas analyzers. Function of nine gas mixer/tonometer systems was evaluated. These were used to create blood samples with target values for PO2 and PCO2. All ten analyzers had high precision; this magnified sm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 1989