Novel, adjustable, clinical bymixer measures mixed expired gas concentrations in anesthesia circle circuit.
نویسندگان
چکیده
UNLABELLED We have introduced a novel, parallel design into a new clinical bymixer (patent pending), named for the bypass of a constant fraction of total flow through a mixing chamber. Over a wide range of tidal volumes (300-1200 mL), frequency (6-20 breaths/min), and PCO(2) (6-50 mm Hg), the bymixer provided accurate measurement of mixed expired gas fractions in the ventilation circuit compared with an expired gas collection in a metabolic lung bench setup (average slope, 1.00; average y intercept, -0.01; average coefficient of determination, R(2) = 0.9988). Simple changes in mixing chamber volume provided adjustable bymixer response times. The fast bymixer response (time constant, 6.4 s) should allow measurements to be updated every 20 s (where 95% response occurs by three time constants). The new clinical bymixer is constructed from standard anesthesia circuit components, attaches easily to the anesthesia machine inspired outlet and expired inlet ports, is simple to clean and sterilize, and has no reservoir to trap condensed water vapor from expired gas. The new clinical bymixer may facilitate indirect calorimetry (CO(2) elimination, VCO(2), and oxygen uptake, VCO(2)) during anesthesia and the noninvasive detection of metabolic upset (e.g., onset of anaerobic metabolism) and critical events (e.g., pulmonary embolism). IMPLICATIONS A new clinical bymixer (inline mixing chamber) provides a fast response and accurate measurements of mixed expired gas fractions in the anesthesia circle circuit. A novel parallel design facilitates adjustable response, easy cleaning, and construction from standard airway circuit components. The new clinical bymixer may facilitate widespread introduction of indirect calorimetry during anesthesia.
منابع مشابه
Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.
BACKGROUND The authors have developed a new clinical bymixer that bypasses a constant fraction of gas flow through a mixing arm. A separate bymixer was interposed in the expiratory and inspiratory limbs of the ventilation circuit to measure mixed gas fractions. By utilizing nitrogen conservation, the clinical bymixer allows the determination of airway carbon dioxide elimination (VCO2) and oxyge...
متن کاملDiscontinuous monitoring of propofol concentrations in expired alveolar gas and in arterial and venous plasma during artificial ventilation.
BACKGROUND Analyzing propofol concentration in expired alveolar gas (cPA) may be considered as a convenient, noninvasive method to follow the propofol concentration in plasma (cPPL). In the current study, the authors established procedures to measure cPA and cPPL for the assessment of their relation in two animal models during anesthesia. METHODS Expired alveolar gas and mixed venous and arte...
متن کاملPredictive accuracy of a model of volatile anesthetic uptake.
UNLABELLED A computer program that models anesthetic uptake and distribution has been in use in our department for 20 yr as a teaching tool. New anesthesia machines that electronically measure fresh gas flow rates and vaporizer settings allowed us to assess the performance of this model during clinical anesthesia. Gas flow, vaporizer settings, and end-tidal concentrations were collected from th...
متن کاملPrevention of airway fires: do not overlook the expired oxygen concentration.
BACKGROUND It is generally accepted that when an ignition source is used the inspired oxygen concentration (FIO2) should be <30% in the breathing circuit to help prevent airway fires. The time and conditions required to reduce a high O2% in the breathing circuit to <30% has not yet been systematically studied. METHODS We evaluated the inspired and expired circuit oxygen concentration response...
متن کاملRelative hysteresis of airspaces and bronchi in excised lungs.
In a steady state the rate of removal of COz from the blood into the alveoli equals its rate of removal from alveoli to atmosphere. There is a gradient of COz concentration from mixed venous blood to alveolar gas or arterial blood and then to mixed expired gas. The mixed venous to alveolar (or arterial) difference depends upon cardiac output (Fick) and the alveolar (or arterial) to mixed expire...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 97 5 شماره
صفحات -
تاریخ انتشار 2003