Accuracy and Utility of Self-report of Refractive Error.
نویسندگان
چکیده
IMPORTANCE Large-scale generic studies offer detailed information on potential risk factors for refractive error across the life course, but ophthalmic examination in such cases to determine the refractive error phenotype is challenging and costly. Thus, refractive status is commonly assigned using questionnaires. In a population survey, often only a few condition-specific self-reported questions can be included, so the questions used must be effective in ruling in those who have the trait of interest and ruling out those who do not. OBJECTIVE To determine the accuracy of identification of refractive status using self-reported age at and/or reason for first use of glasses or contact lenses (optical correction). DESIGN, SETTING, AND PARTICIPANTS The UK Biobank study, a cross-sectional epidemiologic study, included 117 278 participants aged 40 to 69 years in 6 regional centers in England and Wales. Data for the present study were assessed from June 2009 to July 2010. Patients underwent autorefraction measurement. Spherical equivalent in the more extreme eye was used to categorize myopia (-1.00 diopter [D] or more extreme) and hypermetropia (+1.00 D or more extreme). MAIN OUTCOMES AND MEASURES Sensitivity and specificity of the reason for optical correction were assessed using autorefraction as the gold standard. Receiver operating characteristic curves assessed the accuracy of self-reported age at first use of optical correction and incremental improvement with addition of the reason. RESULTS Of the 95 240 participants who reported using optical correction (55.6% female; mean [SD] age, 57.7 [7.5] years), 92 121 (96.7%) provided their age at first use and 93 156 (97.8%) provided the reason. For myopia, sensitivity of the reason for optical correction was 89.1% (95% CI, 88.7%-89.4%), specificity was 83.7% (95% CI, 83.4%-84.0%), and positive and negative predictive values were 72.7% (95% CI, 72.2%-73.1%) and 94.0% (95% CI, 93.8%-94.2%), respectively. The area under the curve was 0.829 (95% CI, 0.826-0.831) and improved to 0.928 (95% CI, 0.926-0.930) with combined information. By contrast, self-report of the reason for optical correction of hypermetropia had low sensitivity (38.1%; 95% CI, 37.6%-38.6%), and the area under the curve with combined information was 0.713 (95% CI, 0.709-0.716). CONCLUSIONS AND RELEVANCE In combination, self-report of the reason for and age at first use of optical correction are accurate in identifying myopia. These findings indicate an agreed set of questions could be implemented effectively in large-scale generic population-based studies to increase opportunities for integrated research on refractive error leading to development of novel prevention or treatment strategies.
منابع مشابه
Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm
Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...
متن کاملمقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت
Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...
متن کاملInvestigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification
Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...
متن کاملبررسی فراوانی انواع عیوب انکساری در بیماران مراجعه کننده به درمانگاه چشم پزشکی بیمارستان امام خمینی (ره) ارومیه
Received: 10 March, 2009Accepted: 29 July, 2009 Abstract Background & Aims: Vision is an important indicator of health and life quality. The latest estimates of the World Health Organization indicate that there are 161 million visually impaired people worldwide. The most common reason for impaired vision may be refractive error. This research was performed to determine the frequency of re...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA ophthalmology
دوره 134 7 شماره
صفحات -
تاریخ انتشار 2016