The timing performance of multigap resistive plate chambers (MRPCs) has been tested at the Rossendorf electron linac ELBE. Electrons with energies of 20–40MeV have been used to mimic minimum ionizing hadrons to be detected in large-scale time-of-flight (TOF) detectors for future heavy-ion collision experiments. Referencing the TOF measurement to the accelerator radio frequency, no fast start detector was necessary. A typical time resolution (including contributions from frontend electronics) of about 70 ps has been achieved for individual strips of the multistrip-anode MRPCs. Rate dependencies and detection efficiencies have been investigated. r 2006 Elsevier B.V. All rights reserved.
منابع مشابه
In-Beam Test Results of the Pestov Glass Resistive Plate Counter Prototypes
D. Bartoş1, G. Caragheorgheopol1, F. Dohrmann2, K.D. Hildenbrand3, B. Kaempfer2, R. Kotte2, L. Naumann2, M. Petriş1, M. Petrovici1, V. Simion1, D. Stach2, C. Williams4, and J. Wuestenfeld2 1NIPNE, Bucharest, Romania; 2FZ Dresden Rossendorf, Dresden, Germany; 3GSI, Darmstadt, Germany; 4CERN, Geneva, Switzerland The Compressed Baryonic Matter (CBM) experiment foresees a time-of-flight (TOF) wall ...
متن کاملبررسی تابش کانالی از بلورهای الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE
The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...
متن کاملFirst Lasing of the Elbe Mid-ir Fel
First lasing of the mid-infrared free-electron laser at ELBE was achieved on May 7, 2004. The Radiation Source ELBE at the Forschungszentrum Rossendorf in Dresden is currently under transition from commissioning to regular user operation. Presently the electron linac produces an up to 18 MeV, 1 mA (cw) electron beam which is alotted to generate various kinds of secondary radiation. After the su...
متن کاملEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کاملPredictability of electron cone ratios with respect to linac make and model
In the past, the Radiological Physics Center (RPC) has developed standard sets of photon depth-dose and wedge-factor data, specific to the make, model, and wedge design of the linear accelerator (linac). In this paper, the RPC extends the same concept to electron-cone ratios. Since 1987, the RPC has measured and documented cone-ratio (CR) values during on-site dosimetry review visits to institu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006