Simulation of MREIT using Balanced Steady State Free Precession (b-SSFP) Pulse Sequence

نویسندگان

  • A S Minhas
  • E J Woo
  • R Sadleir
چکیده

Magnetic resonance electrical impedance tomography (MREIT) utilizes the relation between conductivity and magnetic flux density induced by externally injected current to perform conductivity imaging of body tissues. A spin echo pulse sequence has been predominantly used in MREIT to acquire the z-component Bz of the induced magnetic flux density data from MR phase images. Spin echo based MREIT pulse sequences are most stable and successful in producing high-resolution conductivity images in postmortem and in vivo animal and human experiments. In some applications, localization of a physiological event is desirable. Examples may include detection of neural activities through conductivity changes. In such a case, it would be necessary to maximize the sensitivity. In this paper, we suggest using a balanced steady state free precession (b-SSFP) pulse sequence to localize a small conductivity change. The induced magnetic flux density Bz subject to an injection current makes an offresonance phase in b-SSFP signals. We expect the high sensitivity of b-SSFP signals to any off-resonance phase change will be advantageous for detecting a small conductivity change. Using computer simulations, we show the feasibility of functional or time-difference MREIT using the b-SSFP pulse sequence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current-Controlled Alternating Steady State Free Precession for Rapid Conductivity Mapping

Introduction: High resolution cross-sectional conductivity (σ) distribution of biological tissues can be measured with magnetic resonance electrical impedance tomography (MREIT) (1), wherein the magnetic flux density (Bz) induced by current injection through a pair of electrodes synchronized with a MR pulse sequence appears as perturbation in image phase, and then the relation between ∇Bz and ∇...

متن کامل

FMRI using balanced steady-state free precession (SSFP)

Steady-state free precession (SSFP) is a highly-efficient MRI pulse sequence that has been a fairly recent arrival in the functional MRI realm. Several methods for using balanced SSFP to detect the BOLD signal have been proposed to date and will be discussed in this review. After a brief introduction to the general properties of SSFP, this review describes the quite different approaches of tran...

متن کامل

Breast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE

INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...

متن کامل

Balanced Phase Contrast Steady State Free Precession (PC-SSFP): Velocity Encoding by Gradient Inversion

chnique for velocity measurements (PC-SSFP) is presented that combines CINE Phase Contrast (PC) MRI and balanced Steady State Free Precession. Sensitivity to through plane velocities was established by inverting (i.e. negating) the slice select gradient for consecutively executed balanced SSFP pulse sequences. Velocity sensitivity (venc) could be adjusted by increasing the first moments of the ...

متن کامل

Ultrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast

INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...