Fourier ptychographic microscopy (FPM) is a computational imaging technique with both high resolution and large field-of-view. However, the effective numerical aperture (NA) achievable with a typical LED panel is ambiguous and usually relies on the repeated tests of different illumination NAs. The imaging quality of each raw image usually depends on the visual assessments, which is subjective and inaccurate especially for those dark field images. Moreover, the acquisition process is really time-consuming. In this paper, we propose a SNR-based adaptive acquisition method for quantitative evaluation and adaptive collection of each raw image according to the signal-to-noise ration (SNR) value, to improve the FPM’s acquisition efficiency and automatically obtain the maximum achievable NA, reducing the time of collection, storage and subsequent calculation. The widely used EPRY-FPM algorithm is applied without adding any algorithm complexity and computational burden. The performance has been demonstrated in both USAF targets and biological samples with different imaging sensors respectively, which have either Poisson or Gaussian noises model. Further combined with the sparse LEDs strategy, the number of collection images can be shorten to around 25 frames while the former needs 361 images, the reduction ratio can reach over 90%. This method will make FPM more practical and automatic, and can also be used in different configurations of FPM. References and links 1. G. Zheng, R. Horstmeyer, and C. Yang, “Wide-field, high-resolution Fourier ptychographic microscopy,” Nat. Photonics 7(9), 739–745 (2013). 2. L. Tian, and L. Waller, “3D intensity and phase imaging from light field measurements in an LED array microscope,” Optica 2(2), 104–111 (2015). 3. R. Horstmeyer, J. Chung, X. Ou, G. Zheng, and C. Yang, “Diffraction tomography with Fourier ptychography,” Optica 3(8), 827-835 (2016). 4. J. Holloway, Y. Wu, M. Sharma, O. Cossairt, and A. Veeraraghavan, “SAVI: Synthetic apertures for long-range subdiffraction-limited visible imaging using Fourier ptychography,” Sci. Adv. 3, e1601564 (2017). 5. J. Sun, C. Zuo, L. Zhang, and Q. Chen, “Resolution-enhanced Fourier ptychographic microscopy based on high-numerical-aperture illuminations,” Sci. Rep. 7, 1187 (2017). 6. S. Dong, Z. Bian, R. Shiradkar, and G. Zheng, “Sparsely sampled Fourier ptychography,” Opt. Express 22(5), 5455–5464 (2014). 7. L. Bian, J. Suo, G. Situ, G. Zheng, F. Chen, Q. Dai, “Content adaptive sparse illumination for Fourier ptychography,” Opt. Lett. 39(23), 6648–6651 (2014). 8. R. C. Gonzalez, and R. E. Woods, Digital Image Processing (Prentice Hall, 2007). 9. Y. Zhang, W. Jiang, L. Tian, L. Waller, and Q. Dai, “Self-learning based Fourier ptychographic microcropy,” Opt. Express 23(14), 18471-18486 (2015). 10. K. Guo, S. Dong, P. Nanda, and G. Zheng, “Optimization of sampling pattern and the design of Fourier ptychographic illuminator,” Opt. Express 23(5), 6171-6180 (2015). 11. L. Tian, X. Li, K. Ramchandran, and L. Waller, “Multiplexed coded illumination for Fourier ptychography with an LED array microscope,” Biomed. Opt. Express 5(7), 2376–2389 (2014). 12. L. Tian, and L. Waller, “Quantitative differential phase contrast imaging in an LED array microscope,” Opt. Express 23(9), 11394-11403 (2015). 13. L. Tian, Z. Liu, L. H. Yeh, M. Chen, J. Zhong, and L. Waller, “Computational illumination for high-speed in vitro Fourier ptychographic microscopy,” Optica 2(10), 904–911 (2015). 14. J. Sun, Q. Chen, Y. Zhang, and C. Zuo, “Sampling criteria for Fourier ptychographic microscopy in object space and frequency space,” Opt. Express 24(14), 15765-15781 (2016). 15. Z. Phillips, M. D'Ambrosio, L. Tian, J. Rulison, H. Patel, N. Sadras, A. Gamde, N. Switz, D. Fletcher, and L. Waller, “Multi-contrast imaging and digital refocusing on a mobile microscope with a domed LED array,” Plos One 10(5), e0124938 (2015). 16. C. Kuang, Y. Ma, R. Zhou, J. Lee, G. Barbastathis, R. Dasari, Z. Yaqoob, and P. So, “Digital micromirror device-based laser-illumination Fourier ptychographic microscopy,” Opt. Express 23(21), 26999-27010 (2015). 17. L. Yeh, J. Dong, J. Zhong, L. Tian, M. Chen, G. Tang, M. Soltanolkotabi, and L. Waller, “Experimental robustness of Fourier ptychography phase retrieval algorithms,” Opt. Express 23(26), 33214-33240 (2015). 18. Y. Fan, J. Sun, Q. Chen, M. Wang, and C. Zuo, “Adaptive denoising method for Fourier ptychographic microscopy,” Opt. Commun. (2017) (To be published). 19. Y. Zhang, A. Pan, M. Lei, and B. Yao, “Data preprocessing methods for robust Fourier ptychographic microscopy,” arXiv preprint arXiv: 1707.03716 (2017). 20. C. Wang, Z. Xu, H. Liu, Y. Wang, J. Wang, and R. Tai, “Background noise removal in x-ray ptychography,” Appl. Opt. 56(8), 2099-2110 (2017). 21. P. Thibault, and M. Guizar-Sicairos, “Maximum-likelihood refinement for coherent diffractive imaging,” New J. Phys. 14, 063004 (2012). 22. H. Li, Y. Huang, C. Kuang, and X. Liu, “Method of super-resolution based on array detection and maximumlikehood estimation,” Appl. Opt. 55(35), 9925-9931 (2016). 23. X. Ou, G. Zheng, and C. Yang, “Embedded pupil function recovery for Fourier ptychographic microscopy,” Opt. Express 22(5), 4960–4972 (2014). 24. J. Sun, Q. Chen, Y. Zhang, and C. Zuo, “Efficient positional misalignment correction method for Fourier ptychographic microscopy,” Biomed. Opt. Express 7(3), 1336–1350 (2016). 25. C. Zuo, J. Sun, and Q. Chen, “Adaptive step-size strategy for noise-robust Fourier ptychographic microscopy,” Opt. Express 24(18), 20724-20744 (2016). 26. L. Bian, J. Suo, J. Chung, X. Ou, C. Yang, F. Chen, and Q. Dai, “Fourier ptychographic reconstruction using Poisson maximum likelihood and truncated Wirtinger gradient,” Sci. Rep. 6, 27384 (2016). 27. L. Bian, G. Zheng, K. Guo, J. Suo, C. Yang, F. Chen, and Q. Dai, “Motion-corrected Fourier ptychography,” Biomed. Opt. Express 7(11), 4543-4553 (2016). 28. S. Pacheco, G. Zheng, and R. Liang, “Reflective Fourier ptychography,” J. Biomed. Opt. 21(2), 026010 (2016). 29. X. Ou, I. Chung, R. Horstmeyer, and C. Yang, “Aperture scanning Fourier ptychographic microscopy,” Biomed. Opt. Express 7(8), 3140-3150 (2016). 30. J. Chuang, J. Kim, X. Ou, R. Horstmeyer, and C. Yang, “Wide field-of-view fluorescence image deconvolution with aberration-estimation from Fourier ptychography,” Biomed. Opt. Express 7(2), 352-368 (2016).
منابع مشابه
2 3 M ar 2 01 6 Wide - field Fourier ptychographic microscopy using laser illumination source
Fourier ptychographic (FP) microscope is a coherent imaging method that can synthesize an image with a higher bandwidth using multiple low-bandwidth images captured at different spatial frequency regions. The method’s demand for multiple images drives the need for a brighter illumination scheme and a high-frame-rate camera for a faster acquisition. We report the use of a guided laser beam as an...
متن کاملFourier ptychographic reconstruction using Poisson maximum likelihood and truncated Wirtinger gradient
Fourier ptychographic microscopy (FPM) is a novel computational coherent imaging technique for high space-bandwidth product imaging. Mathematically, Fourier ptychographic (FP) reconstruction can be implemented as a phase retrieval optimization process, in which we only obtain low resolution intensity images corresponding to the sub-bands of the sample's high resolution (HR) spatial spectrum, an...
متن کاملFast and robust misalignment correction of Fourier ptychographic microscopy
Fourier ptychographic microscopy (FPM) is a newly developed computational imaging technique that can provide gigapixel images with both high resolution (HR) and wide field of view (FOV). However, the position misalignment of the LED array induces a degradation of the reconstructed image, especially in the regions away from the optical axis. In this paper, we propose a robust and fast method to ...
متن کاملLow Rank Fourier Ptychography
In this paper, we introduce a principled algorithmic approach for Fourier ptychographic imaging of dynamic, time-varying targets. To the best of our knowledge, this setting has not been explicitly addressed in the ptychography literature. We argue that such a setting is very natural, and that our methods provide an important first step towards helping reduce the sample complexity (and hence acq...
متن کاملWide-field Fourier ptychographic microscopy using laser illumination source.
Fourier ptychographic (FP) microscopy is a coherent imaging method that can synthesize an image with a higher bandwidth using multiple low-bandwidth images captured at different spatial frequency regions. The method's demand for multiple images drives the need for a brighter illumination scheme and a high-frame-rate camera for a faster acquisition. We report the use of a guided laser beam as an...