Development and validation of a complete GATE model of the Siemens Inveon trimodal imaging platform.

نویسندگان

  • Sanghyeb Lee
  • Jens Gregor
  • Dustin Osborne
چکیده

This article presents and validates a newly developed GATE model of the Siemens Inveon trimodal imaging platform. Fully incorporating the positron emission tomography (PET), single-photon emission computed tomography (SPECT), and computed tomography (CT) data acquisition subsystems, this model enables feasibility studies of new imaging applications, the development of reconstruction and correction algorithms, and the creation of a baseline against which experimental results for real data can be compared. Model validation was based on comparing simulation results against both empirical and published data. The PET modality was validated using the NEMA NU-4 standard. Validations of SPECT and CT modalities were based on assessment of model accuracy compared to published and empirical data on the platform. Validation results show good agreement between simulation and empirical data of approximately ± 5%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation and evaluation of a GATE model for MAMMI PET scanner

Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard.  Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...

متن کامل

Comparative Study of Imaging Characteristics of I-125 Imaging Using the Siemens Inveon Scanner and Siemens Symbia TruePoint

Objective: Although Iodine-125 (125I) has been widely used for in vitro studies because of its relatively long half-life (60.1 days), 125I imaging is limited because of its low energy (27 35 keV), even in an animal-dedicated system. In this study, imaging characteristics of 125I were assessed using a small animal-dedicated imaging system and clinical scanner. Methods: Using the Siemens Inveon a...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Field Programmable Gate Array–based Implementation of an Improved Algorithm for Objects Distance Measurement (TECHNICAL NOTE)

In this work, the design of a low-cost, field programmable gate array (FPGA)-based digital hardware platform that implements image processing algorithms for real-time distance measurement is presented. Using embedded development kit (EDK) tools from Xilinx, the system is developed on a spartan3 / xc3s400, one of the common and low cost field programmable gate arrays from the Xilinx Spartan fami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Molecular imaging

دوره 12 7  شماره 

صفحات  -

تاریخ انتشار 2013