Comparison of a xenogeneic and an alloplastic material used in dental implants in terms of physico-chemical characteristics and in vivo inflammatory response.

نویسندگان

  • Andreia Figueiredo
  • Patrícia Coimbra
  • António Cabrita
  • Fernando Guerra
  • Margarida Figueiredo
چکیده

Two commercial bone grafts used in dentistry (Osteobiol Gen-Os®, a xenograft of porcine origin, and Bonelike®, a hydroxyapatite based synthetic material), in the form of granules, were characterized and evaluated in vivo regarding the intensity of the tissue inflammatory response. These biomaterials were characterized in terms of morphology, particle size distribution, porosity and pore size, specific surface area and density. The chemical composition and structure of the materials were accessed by Fourier-Transform Infrared Spectroscopy (FTIR) and X-ray Diffraction (XRD). The graft materials were implanted in the gluteus maximus muscles of Wistar rats and the inflammatory response was evaluated through histological analysis, after one week of implantation. The results showed that the two grafts have quite different characteristics in practically all the evaluated properties. While Osteobiol® exhibits a structure and composition similar to the natural bone, Bonelike® is constituted by a main crystalline phase of hydroxyapatite and two secondary phases of α- and β-tricalcium phosphate. Osteobiol® granules, besides being larger, are irregular, and exhibit sharp-edged tips, while those of Bonelike® are approximately cylindrical, with round contours, and more uniform in size. The in vivo response evaluated from the inflammatory infiltrates revealed that although both implants did not cause severe inflammation, Bonelike® granules elicit a consistently more intense inflammatory reaction than that triggered by the granules of Osteobiol®, particularly in terms of collagen production and formation of fibrous capsule. This reaction was partly explained in terms of the characteristics evaluated for the granules of this material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Nd: Yag Laser Radiation Effects on Ti6Al4V Physico-Chemical Properties: An In Vivo Study

The effect of a Nd: YAG laser (1064 nm) has been studied on Ti6Al4V alloy in terms of optical and physical parameters for biomedical applications. The superior surface microhardness hardness (i.e. 377 VHN) is attributed to grain refinement associated with laser melting and rapid solidification. The electrochemical property, mainly pitting corrosion resistance, has been carried out in Hanks salt...

متن کامل

Adult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces

Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...

متن کامل

The Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success

Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...

متن کامل

The Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success

Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...

متن کامل

Cure Characteristics and Physico-mechanical Properties of the Stearic Acid Surface of Modified Calcium Carbonate Reinforcement NR/SBR Compounds

Calcium carbonate is a cheap and readily available filler used in rubber industry. This material is not compatible with rubber matrix, so many researchers have tried to modify its surface with various materials in order to increase its hydrophobicity and improve compatibility with the rubber matrix. In this effort, surface modification of calcium carbonate was carried out by 1.5%, 3% and 4% ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Materials science & engineering. C, Materials for biological applications

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2013