Multiorder correction algorithms to remove image distortions from mass spectrometry imaging data sets.

نویسندگان

  • Florian Gerber
  • Florian Marty
  • Gert B Eijkel
  • Konrad Basler
  • Erich Brunner
  • Reinhard Furrer
  • Ron M A Heeren
چکیده

Time-of-flight secondary ion mass spectrometry imaging is a rapidly evolving technology. Its main application is the study of the distribution of small molecules on biological tissues. The sequential image acquisition process remains susceptible to measurement distortions that can render imaging data less analytically useful. Most of these artifacts show a repetitive nature from tile to tile. Here we statistically describe these distortions and derive two different algorithms to correct them. Both a generalized linear model approach and the linear discriminant analysis approach are able to increase image quality for negative and positive ion mode data sets. Additionally, performing simulation studies with repetitive and nonrepetitive tiling error we show that both algorithms are only removing repetitive distortions. It is further shown that the spectral component of the data set is not altered by the use of these correction methods. Both algorithms presented in this work greatly increase the image quality and improve the analytical usefulness of distorted images dramatically.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperspectral Imaging System Optimization and Image Processing

In the research of remote sensing for precision farming applications, the data quality of the aerial hyperspectral imaging system suffers from geometric distortions. Some of the distortions are caused by aircraft attitude change during the current pushbroom type image scanning. These distortions must be corrected before image data can be geo-referenced and used for field pattern identifications...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

Computational Algorithm for Modeling and Correction of Gradient Nonlinearity Distortions in Magnetic Resonance Imaging

Targeting of brain tumors or diseased brain tissues with neurosurgical instruments or radiosurgery beams requires magnetic resonance image (MRI) sets with high spatial resolution. In recent years, the spatial resolution of MRI scanners has increased considerably with the introduction of highfield (3T) technology. As a result, isotropic submillimeter voxel sizes are more commonly being used for ...

متن کامل

A Novel NeighShrink Correction Algorithm in Image Denoising

Image denoising as a pre-processing stage is a used to preserve details, edges and global contrast without blurring the corrupted image. Among state-of-the-art algorithms, block shrinkage denoising is an effective and compatible method to suppress additive white Gaussian noise (AWGN). Traditional NeighShrink algorithm can remove the Gaussian noise significantly, but loses the edge information i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 85 21  شماره 

صفحات  -

تاریخ انتشار 2013