Indoor particles and symptoms among office workers: results from a double-blind cross-over study.
نویسندگان
چکیده
BACKGROUND We studied the effects of removing small airborne particles in an office building without unusual contaminant sources or occupant complaints. METHODS We conducted a double-blind crossover study of enhanced particle filtration in an office building in the Midwest United States in 1993. We replaced standard particle filters, in separate ventilation systems on two floors, with highly efficient filters on alternate floors weekly over 4 weeks. Repeated-measures models were used to analyze data from weekly worker questionnaires and multiple environmental measurements. RESULTS Bioaerosol concentrations were low. Enhanced filtration reduced concentrations of the smallest airborne particles by 94%. This reduction was not associated with reduced symptoms among the 396 respondents, but three performance-related mental states improved; for example, the confusion scale decreased (-3.7%; 95% confidence limits (CL) = -6.5, -0.9). Most environmental dissatisfaction variables also improved; eg, "stuffy" air, -5.3% (95% CL = -10.3, -0.4). Cooler temperatures within the recommended comfort range were associated with remarkably large improvement in most outcomes; for example, chest tightness decreased -23.4% (95% CL = -38.1, -8.7) for every 1 degrees C decrease. CONCLUSIONS Benefits of enhanced filtration require assessment in buildings with higher particulate contaminant levels in studies controlling for temperature effects. Benefits from lower indoor temperatures need confirmation.
منابع مشابه
مطالعه علائم سندرم ساختمان بیمار در کارکنان اداری سازمان بهداشت و درمان صنعت نفت
Background­ and objectives : Research has consistently shown that air quality personal factors and work related factors were the most effective parameters for sick building syndrome. Several epidemiological studies have been carried out to show the prevalence of the sick building syndrome among the office workers but less attention has been paid to the relation of the sick building s...
متن کاملبررسی ارتباط فاکتورهای روانی-اجتماعی مرتبط با کار در بروز اختلالات ناحیه گردن در پرسنل اداری دانشگاه علوم پزشکی شیراز
Background and aims: Neck disorders among office workers are one of the main causes of the increase in the job absence, Jobs turnover and health care costs. Different factors are attributed to the occurrence of neck disorders. This study was carried out to investigate the association of psychosocial factors associated with the incidence of neck disorders in office workers of Shiraz University o...
متن کاملبررسی علائم و نشانههای سندرم ساختمان بیمار در کارکنان اداری دانشگاه علوم پزشکی شهید صدوقی یزد در سال 1387
Background and aims Building associated illnesses are a group of illnesses caused by physical or psychological conditions of workplace. One of theses illnesses is sick building syndrome (SBS) which consists of a group of symptoms, including mucosal irritation, headache, fatigue, skin dryness and itching, and nausea that are temporally related to presence in a particular building. This study wa...
متن کاملGender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia
OBJECTIVES The purpose of this study was to analyze the relationship of airborne chemicals and the physical work environment risk element on the indoor air symptoms of nonindustrial workers. DESIGN A cross-sectional study consisting of 200 office workers. A random selection of 200 buildings was analyzed for exposure and indoor air symptoms based on a pilot study in the Klang Valley, Malaysia....
متن کاملEffect of ultraviolet germicidal lights installed in office ventilation systems on workers' health and wellbeing: double-blind multiple crossover trial.
BACKGROUND Workers in modern office buildings frequently have unexplained work-related symptoms or combinations of symptoms. We assessed whether ultraviolet germicidal irradiation (UVGI) of drip pans and cooling coils within ventilation systems of office buildings would reduce microbial contamination, and thus occupants' work-related symptoms. METHODS We undertook a double blind, multiple cro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Epidemiology
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2002