Statistical analysis of stereoacuity in ophthalmology research
نویسندگان
چکیده
We read the interesting article entitled: “Stereoacuity after photorefractive keratectomy in myopia” by Zarei-Ghanavati et al. As we already published, data from stereopsis tests may need special care for analysis. By nature, the results of stereoacuity tests followageometrical sequence bymultiplying at a ratio. For example, if we have 120 s of arc of stereoacuity in a subject and480 in another, itmeans that the result at the secondperson is4 timesworse than the first one. This is differentwithmeasurements that follow an arithmetic sequence like ocular axial length in which a difference of length of 23 and 20 mm means the first number is the second number plus 3 mm. The functional consequence from a statistical standpoint would be that distribution of actual data of a geometrical sequence is expected to be highly skewed, although with regard to the central limit theorem, the distribution of the sample could be near normal enough to pass a normality test. To work on data with geometric sequence properties, the skewness problem could easily be overcome by converting the data to the logarithm of them. A logarithm of the data with geometric sequence will be an arithmetic sequence, much easier to performmathematical and statistical evaluation on. This phenomenon iswell knownandwidely accepted in evaluationand analyzing the visual acuity data from the 19th century. For better statistical efficiency, we suggest to convert stereoacuity seconds of arc values to logarithm of second of arc and check the distribution plots.
منابع مشابه
Pitfalls in the Use of Stereoacuity in the Diagnosis of Nonorganic Visual Loss.
PURPOSE The Titmus Stereotest (Stereo Optical Co., Inc., Chicago, IL) has been used to estimate visual acuity (VA) in the evaluation of nonorganic visual loss. Previous predictions were derived from optical degradation of VA in normal subjects and may not account for the variability seen in patients with neuro-ophthalmic pathologies included in the differential diagnosis of nonorganic visual lo...
متن کاملFrisby Davis distance stereoacuity values in visually normal children.
AIMS To establish the range of normal distance stereoacuity in young children using the Frisby Davis distance stereo test (FD2). METHODS Children passing preschool vision screening assessments underwent measurement of distance stereoacuity with the FD2 using a standard testing protocol. RESULTS 59 visually normal children aged between 36 months and 68 months were recruited to this study. Al...
متن کاملVariability of stereoacuity in intermittent exotropia.
PURPOSE Distance stereoacuity is used to monitor deterioration of intermittent exotropia (IXT), but variability of stereoacuity has not been studied rigorously. The purpose of this study was to assess the variability of stereoacuity over one day in children with IXT. DESIGN Prospective cohort study. METHODS Twelve children with IXT were recruited. Stereoacuity was assessed using the Frisby ...
متن کاملA study on the clinical usefulness of digitalized random-dot stereoacuity test.
Existing methods of stereoacuity testing need specific glasses or optical device for use. We have designed a new stereoacuity test for the digitalized, random-dot stereogram and researched its clinical usefulness. A digitalized, random-dot, stereoacuity test card was created with a computer program that used a preferred symbol and the designed system was tested along with the Randot preschool s...
متن کاملFactors influencing stereoacuity levels after surgery to correct unilateral developmental cataracts in children.
AIM To evaluate factors influencing stereoacuity after surgery to correct unilateral developmental pediatric cataracts. METHODS We retrospectively surveyed 110 patients who had undergone removal of unilateral acquired developmental cataracts and primary posterior chamber intraocular lens implantation between February 1992 and December 2009. In all patients, stereoacuity was assessed using the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 28 شماره
صفحات -