Three-dimensional reconstructed magnetic resonance scans: Accuracy in identifying and defining knee meniscal tears

نویسندگان

  • Neil Kruger
  • Eugene McNally
  • Sami Al-Ali
  • Raj Rout
  • Jonathan L Rees
  • Andrew J Price
چکیده

AIM To determine whether three-dimensional (3D) reconstruction from conventional magnetic resonance imaging (MRI) is able to accurately detect a meniscal tear, and define the configuration. METHODS Thirty-three patients' 3T MRI scan data were collected and sagittal uni-planar 3D reconstructions performed from the preoperative MRI. There were 24 meniscal tears in 24 patients, and nine controls. All patients had arthroscopic corroboration of MRI findings. Two independent observers prospectively reported on all 33 reconstructions. Meniscal tear presence or absence was noted, and tear configuration subsequently categorised as either radial, bucket-handle, parrot beak, horizontal or complex. RESULTS Identification of control menisci or meniscal tear presence was excellent (Accuracy: observer 1 = 90.9%; observer 2 = 81.8%). Of the tear configurations, bucket handle tears were accurately identified (Accuracy observer 1 and 2 = 80%). The remaining tear configurations were not accurately discernable. CONCLUSION Uni-planar 3D reconstruction from 3T MRI knee scan sequences are useful in identifying normal menisci and menisci with bucket-handle tears. Advances in MRI sequencing and reconstruction software are awaited for accurate identification of the remaining meniscal tear configurations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Imaging of the Knee

Magnetic resonance imaging (MRI) is an accepted non-invasive modality for evaluation of soft tissue pathology without exposure to ionizing radiation. Current applications demonstrate excellent visualization of the anatomy and pathology of various organs. Preliminary studies in the knee reveal fine resolution of anatomy and pathology involving the meniscus. The purpose of this study is to determ...

متن کامل

Diagnostic accuracy of a new clinical test (the Thessaly test) for early detection of meniscal tears.

BACKGROUND Clinical tests used for the detection of meniscal tears in the knee do not present acceptable diagnostic sensitivity and specificity values. Diagnostic accuracy is improved by arthroscopic evaluation or magnetic resonance imaging studies. The objective of this study was to evaluate the diagnostic accuracy of a new dynamic clinical examination test for the detection of meniscal tears....

متن کامل

Diagnostic performance of 3D TSE MRI versus 2D TSE MRI of the knee at 1.5 T, with prompt arthroscopic correlation, in the detection of meniscal and cruciate ligament tears*

OBJECTIVE To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. MATERIALS AND METHODS Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR t...

متن کامل

A novel and non-destructive method to examine meniscus architecture using 9.4 Tesla MRI

OBJECTIVE To investigate the ability of high-field (9.4 T) magnetic resonance (MR) imaging to delineate porcine knee meniscal tissue structure and meniscal tears. MATERIALS AND METHODS Porcine knees were obtained from a local abattoir, and eight medial menisci with no visible defects were dissected. Lesions simulating longitudinal tears were created on two of the menisci. MR images of the men...

متن کامل

Diagnostic accuracy of Magnetic Resonance Imaging in assessment of Meniscal and ACL tear: Correlation with arthroscopy

OBJECTIVE To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in injuries related to anterior cruciate ligament and menisci and compare its effectiveness with that of arthroscopy. METHODS This retrospective cross-sectional study was conducted in the department of Radiology & Medical Imaging of Dallah Hospital, Riyadh, Kingdom of Saudi Arabia from September 2012 to March 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -