Optical coherence tomography as a tracking device for OCT guided laser cochleostomy: algorithm and first results
نویسندگان
چکیده
Conventional optical tracking systems have accuracy on the scale of several hundred micrometers. This is insufficient for an optical coherence tomography (OCT) guided laser cochleostomy which requires a much higher accuracy. In this paper, we evaluate the use of OCT itself as a tracking device by locating artificial landmarks generated around the cochleostomy. The results of the first experiments indicate that it is possible to achieve a mean absolute error of ca. 30μm for a single landmark using the proposed algorithm. An even smaller error is expected when at least 3-4 landmarks are used for the 3D tracking. The algorithm can be also used for the calibration and registration between the OCT and the laser ablation systems.
منابع مشابه
Feasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach
Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملOptical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded soft tissue. In this work, we demonstrate a closed-loop control of a short-pulsed CO2 laser to per...
متن کاملEffects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study
Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...
متن کاملOptical coherence tomography as a guide for cochlear implant surgery?
Optical coherence tomography as a guide for cochlear implant surgery? To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal...