Compensation method for respiratory motion in proton treatment planning for mobile liver cancer

نویسندگان

  • Hojin Jeong
  • Se Byeong Lee
  • Seung Hoon Yoo
  • Young Kyung Lim
  • Tae Hyun Kim
  • Seyjoon Park
  • Gyu Young Chai
  • Ki Mun Kang
  • Dongho Shin
چکیده

We evaluated the dosimetric effect of a respiration motion, and sought an effective planning strategy to compensate the motion using four-dimensional computed tomography (4D CT) dataset of seven selected liver patients. For each patient, we constructed four different proton plans based on: (1) average (AVG) CT, (2) maximum-intensity projection (MIP) CT, (3) AVG CT with density override of tumor volume (OVR), and (4) AVG CT with field-specific proton margin which was determined by the range difference between AVG and MIP plans (mAVG). The overall effectiveness of each planning strategy was evaluated by calculating the cumulative dose distribution over an entire breathing cycle. We observed clear differences between AVG and MIP CT-based plans, with significant underdosages at expiratory and inspiratory phases, respectively. Only the mAVG planning strategy was fully successful as the field-specific proton margin applied in the planning strategy complemented both the limitations of AVG and MIP CT-based strategies. These results demonstrated that respiration motion induced significant changes in dose distribution of 3D proton plans for mobile liver cancer and the changes can be effectively compensated by applying field-specific proton margin to each proton field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Calculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code

Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver.   Materials and Methods: For si...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Direct Optimal Motion Planning for Omni-directional Mobile Robots under Limitation on Velocity and Acceleration

This paper describes a low computational direct approach for optimal motion planning and obstacle avoidance of Omni-directional mobile robots within velocity and acceleration constraints on the robot motion. The main purpose of this problem is the minimization of a quadratic cost function while limitation on velocity and acceleration of robot is considered and collision with any obstacle in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013