Contractility-dependent curvilinearity of end-systolic pressure-volume relations.
نویسندگان
چکیده
The shape of the end-systolic tension-length relationship (ESTLR) changes when contractile state is changed, whereas the end-systolic pressure-volume relationship (ESPVR) remains linear despite changes in contractility. To investigate this disparity, the ESPVR was determined with contractility altered extensively by dobutamine, BAY K 8644, nifedipine, lowering coronary blood flow, and the introduction of extrasystolic and postextrasystolic stimulations. The ESPVRs were fitted by nonlinear regression analysis to the parabolic equation Pes = aVes2 + bVes + c, where Pes is end-systolic pressure, Ves is end-systolic volume, and a, b, and c are parameters. There was a negative, statistically significant correlation between a, which serves as a shape index of the ESPVR, and E'max, the slope of the ESPVR in a low volume range. When E'max was large a was negative, indicating increasing concavity of the ESPVR to the volume axis at high contractility. When E'max was small a was positive, indicating convexity of the ESPVRs to the volume axis at low contractility. Within the average range of E'max between 3.4 and 7.8 mmHg/ml, however, the parabolic fit to the data was not statistically better than a linear fit over the range of volumes testable in the isolated heart. We conclude that the shape of the ESPVR measured in the isolated canine heart changes with contractile state. In accordance with previous interpretations of shape changes in the muscle ESTLR, these results are consistent with the existence of length-dependent activation of cardiac muscle in the intact heart.
منابع مشابه
Curvilinearity of In Situ End-Systolic Pressure-Volume Relations
Although in situ end-systolic pressure-volume relations (ESPVRs) are approximately linear throughout a limited load range, they often yield seemingly "1negative" volume axis intercepts (V0) and V0 shifts with inotropic interventions. We tested whether or not these findings could stem from in situ ESPVR nonlinearity, and we examined the physiologic meaning and limitations of linearized ESPVR var...
متن کاملInfluence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.
Although in situ end-systolic pressure-volume relations (ESPVRs) are approximately linear throughout a limited load range, they often yield seemingly "negative" volume axis intercepts (V0) and V0 shifts with inotropic interventions. We tested whether or not these findings could stem from in situ ESPVR nonlinearity, and we examined the physiologic meaning and limitations of linearized ESPVR vari...
متن کاملESPVR of in situ rat left ventricle shows contractility-dependent curvilinearity.
We developed a miniaturized conductance catheter for in situ rat left ventricular (LV) volumetry. After the validation study of the conductance volumetry in 11 rats, we characterized the end-systolic pressure-volume relationship (ESPVR) in 24 sinoaortic-denervated, vagotomized and urethan-anesthetized rats. Stroke volume (SV) measured with the conductance catheter correlated closely with that m...
متن کاملPreload-induced curvilinearity of left ventricular end-systolic pressure-volume relations. Effects on derived indexes in closed-chest dogs.
End-systolic pressure-volume relations (ESPVRs) were analyzed in 10 closed-chest autonomically blocked dogs before and after volume loading that restored end-diastolic volume to its value measured in the control conscious state. Dogs had been previously instrumented with a left ventricular pressure micromanometer and ultrasonic crystals for measurements of major, anteroposterior, and septum-fre...
متن کاملLeft ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.
OBJECTIVE To assess independent determinants of beat to beat variation in left ventricular performance during atrial fibrillation. DESIGN Prospective study. SETTING University hospital. PATIENTS Seven patients with chronic non-valvar atrial fibrillation. INTERVENTIONS Invasive and non-invasive haemodynamic variables were assessed using a non-imaging computerised nuclear probe, a balloon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of physiology
دوره 252 6 Pt 2 شماره
صفحات -
تاریخ انتشار 1987