Periferic intravenous infusion of fenoldopam through an elastomeric pump
نویسندگان
چکیده
INTRODUCTION Fenoldopam has been used to protect renal function in critically ill patients and in those undergoing major surgery, where a possible damage of kidney is expected. Numerous randomized studies and meta-analysis demonstrated the efficacy of fenoldopam in this setting. We performed this study to demonstrate the feasibility of administering fenoldopam, trough an elastomeric pump connected to a peripheral vein, to patients undergoing nephron sparing surgery. MATERIALS AND METHODS Twenty consecutive patients, ASA physical status class I-III, undergoing laparoscopic or laparotomic renal tumorectomy were enrolled. Fenoldopam was infused trough an elastomeric pump at a fixed dosage of 0.1 mcg/kg/min, obtained after diluting the drug with saline solution according to the weight of the patient. We injected the drug trough a peripheral vein from the induction of anaesthesia for 48 hours after the end of surgery. RESULTS The infusion of fenoldopam did not modify the haemodynamic parameters. We did not find episodes of hypotension and only in three patients we registered episodes of tachycardia, not requiring the suspension of the infusion. No other side-effect was noted. CONCLUSIONS The administration of fenoldopam, trough an elastomeric pump, in patients undergoing renal tumorectomy is feasible through a peripheral vein access.
منابع مشابه
Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study
INTRODUCTION Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Seconda...
متن کاملChemical Stability of Ceftolozane/Tazobactam in Polyvinylchloride Bags and Elastomeric Pumps
BACKGROUND Elastomeric pumps are often used to administer intravenous antibiotics in the outpatient setting, but effective infusion requires that the drug remain stable in solution throughout the procedure. OBJECTIVE To determine the chemical stability of ceftolozane/tazobactam when reconstituted and stored over an extended time in the AccuFlo (EMED Technologies, El Dorado Hills, California) ...
متن کاملIntravenous fenoldopam versus sodium nitroprusside in patients with severe hypertension.
In an open-label study, we compared the efficacy and safety of intravenous infusion of fenoldopam mesylate with that of sodium nitroprusside in patients with severe hypertension or in hypertensive crisis. Both antihypertensive medications were infused at a maximal dose increment of 0.2 microgram/kg/min (fenoldopam) and 1 microgram/kg/min (nitroprusside), with a maximal infusion rate of 1.5 micr...
متن کاملAntihypertensive Bridge Therapy by Continuous Drug Infusion With an Elastomeric Pump in Device-Resistant Hypertension.
To the Editor: Over recent years, invasive hypertension treatments have led to a new clinical condition, called device-resistant hypertension (DRH).1 DRH is defined as blood pressure (BP) >140/90 mm Hg, with at least 3 antihypertensives at maximal doses, including a diuretic,2 without BP decrease after the invasive treatments. These patients are not infrequent and are obliged to visit several h...
متن کاملThe flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling
BACKGROUND One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. OBJECTIVES Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an ela...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2009