Importance of breath size in calibrating the respiratory inductive plethysmograph.
نویسندگان
چکیده
The usual method of calibrating the respiratory inductive plethysmograph (RIP) is to have the subject breathe over a rather narrow volume range, either resting tidal volume or into a bag containing a fixed larger volume, in both the standing and supine positions. During a previous study in our laboratory using the RIP to quantify ventilation during sleep in young and elderly adults, we began to observe that the accuracy of the RIP measurements could be improved if we calibrated using a wider range of tidal volumes which encompassed the smaller breath sizes we were measuring during sleep. We therefore decided to investigate whether the size of the breaths used for calibrating the RIP was indeed important in improving the accuracy of the device. Eight healthy, nonsmoking young adult men participated in the study. Three sets of calibration factors for the RIP were determined based on low (300 to 500 ml), normal (500 to 800 ml) and high tidal volume (over 800 ml) breaths. Each of these sets of calibration factors were then used to validate three different sets of supine tidal volumes (low, normal, high). For all volumes tested, the RIP values most closely approximated the spirometric volumes when the calibration breaths and validation breaths were of the same size.
منابع مشابه
The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression.
The accuracy of the respiratory inductive plethysmograph (Respitrace) for estimation of lung volume changes during quiet breathing and vital capacity (VC) manoeuvres was evaluated using a variant of the multiple linear regression (MLR) technique. We applied this technique successively on quiet breathing, on the whole VC, and on each of the four quarters of the VC separately. This was carried ou...
متن کاملInitiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کاملBreath-by-breath measurement of particle deposition in the lung of spontaneously breathing rats.
A number of deposition models for humans, as well as experimental animals, have been described. However, no breath-by-breath deposition measurement in rats has been reported to date. The objective of this study is to determine lung deposition of micrometer-sized particles as a function of breathing parameters in the adult rat lung. A new aerosol photometry system was designed to measure deposit...
متن کاملEffect of bronchial challenge on breathing patterns and arterial oxygenation in stable asthma.
The effect of histamine or methacholine inhalational challenge on breathing patterns and oxygen saturation was investigated in ten stable asthmatic patients. We used the respiratory inductive plethysmograph to record respiratory timing and minute ventilation along with an ear oximeter to measure oxygen saturation (SaO2). As FEV1 fell during the challenge procedure, SaO2 also fell (average 3 per...
متن کاملThe efficacy of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women
Introduction: Introduction: The respiratory system affects the motor control and stability of the body, especially in the elderly. The present study aimed to determine the effect of diaphragmatic breathing practice on respiratory function, balance, and quality of life in elderly women. Materials and Methods: Forty elderly women with a mean age of 72.40 years participated in this study voluntari...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 89 6 شماره
صفحات -
تاریخ انتشار 1986