Spectrofluorometric assay for rapid detection of total and fecal coliforms from surface water.
نویسندگان
چکیده
With a spectrofluorometer, the length of the incubation time required in the fluorogenic assay was reduced to 12 h. The threshold emissions for reading the fluorogenic reaction by the spectrofluorometer were 5 and 10 U for lauryl tryptose broth media containing 4-methylumbelliferyl-beta-D-galactoside and 4-methylumbelliferyl-beta-D-glucuronide, respectively. These two kinds of threshold units were equivalent to known concentrations of free 4-methylumbelliferone of 2.5 and 6 microM, respectively, in lauryl tryptose broth media.
منابع مشابه
Rapid Monitoring of Indicator Coliforms in Drinking Water by an Enzymatic Assay
Coliform group has been extensively used as an indicator of drinking water quality and historically led to the public health protection concept. Multiple tube fermentation technique has been currently used for assessment of the microbial quality of drinking water. This method, however, has limitations. Enzymatic assay constitute an alternative approach for detecting indicator bacteria, namely t...
متن کاملRapid determination of the presence of enteric bacteria in water.
A rapid and sensitive method is described for the detection of bacteria in water and various other natural substrates by the isolation of specific bacteriophage. By the addition of large numbers of the organism in question to the sample, the presence of virulent bacteriophage can be demonstrated in as little as 6 to 8 h. Fecal coliform, total coliform, and total coliphage counts were determined...
متن کاملارزیابی توانایی کلستریدیوم پرفرنژنس در تعیین آلودگی مدفوعی آب در مقایسه با باکتری های شاخص
Introduction & Purpose Fecal coliforms and Escherichia coli have been conventionally used as indicators of microbial pollution of drinking water. The European Directive on drinking water quality has included Clostridium perfringens as one of the microbiological parameters to be determined in control of the water quality for human consumption. This study was carried out to evaluate the efficien...
متن کاملRapid detection of total and fecal coliforms in water by enzymatic hydrolysis of 4-methylumbelliferone-beta-D-galactoside.
Three fluorogenic methylumbelliferone (MU) substrates were evaluated for rapid detection of total and fecal coliform bacteria (TC and FC) in drinking water. 4-MU-beta-D-galactoside, MU-heptanoate, and MU-glucuronide were used to determine enzyme activity as a surrogate measure of coliform concentration. Coliforms occurring in river water and in potable water artificially contaminated with raw s...
متن کاملتعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN
Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied and environmental microbiology
دوره 61 5 شماره
صفحات -
تاریخ انتشار 1995