Constraints on the polarization purity of a Stokes microwave radiometer
نویسنده
چکیده
Measurement of the third and fourth Stokes parameters of microwave thermal emission can be degraded by nonideal radiometer characteristics. Of particular importance is the level of polarization purity and the knowledge of polarization impurity on the part of the instrument. An explicit relationship is developed between the true Stokes parameters and the measurements, as functions of nonideal polarization characteristics. In principle, knowledge of the characteristics allows the degradation to be removed by a postprocessing calibration procedure. However, errors in the knowledge are possible, resulting from inexact initial testing and/or subsequent drifting of the instrument. The effects of these errors on overall calibration are considered. It is found that there is considerably greater tolerance to the errors when incoherent detection is used (differencing 6458 linear and leftor right-hand circular polarizations), as opposed to coherent detection (direct cross correlation of vertical and horizontal linear polarizations). This is particularly true when cross-polar leakage is imbalanced. The level of nominal polarization purity that is required is also more relaxed in the incoherent case. On the other hand, coherent detection has the capability for superior performance with regard to precision.
منابع مشابه
35 0 v 2 2 1 Ja n 20 03 A dual output polarimeter devoted to the study of the Cosmic Microwave Background
We have developed a correlation radiometer at 33 GHz devoted to the search for the residual polarization of the Cosmic Microwave Background (CMB). The two instrument’s outputs are a linear combination of two Stokes parameters (Q and U, or U and V). The instrument is therefore directly sensitive to the polarized component of the radiation (respectively linear and circular). The radiometer has a ...
متن کاملar X iv : a st ro - p h / 03 01 35 0 v 1 1 7 Ja n 20 03 A dual output polarimeter devoted to the study of the Cosmic Microwave Background
We have developed a correlation radiometer at 33 GHz devoted to the search for the residual polarization of the Cosmic Microwave Background (CMB). The two instrument’s outputs are a linear combination of two Stokes parameters (Q and U, or U and V). The instrument is therefore directly sensitive to the polarized component of the radiation (respectively linear and circular). The radiometer has a ...
متن کاملA Spaceborne Microwave Radiom Ocean Wind Remote
In this thesis, the design of a spaceborne passive radar is pre ented for the remote sensing of wind vector at the surface of the ocean. Its bases are the 10.35 and 37 GHz radiometers built at the Jet Propulsion Lab at Caltech in Pasadena, Califctnia which have been tested in airborne configurations aboard the NASA DC-8. The radioneter detects orthogonal linear polarization brightness temperatu...
متن کاملPassive Microwave Remote Sensing of Tropical Cyclones
Passive microwave radiometers have a strong heritage of instruments: the Special Sensor Microwave Imager (SSM/I), the Tropical Rainfall Mapping Mission (TRMM) Microwave Imager (TMI), the Advanced Microwave Scanning Radiometer–Earth Observing (AMSR-E) and the Special Sensor Microwave Imager/Sounder (SSMI/S). These instruments measure vertically and horizontally polarized brightness temperatures ...
متن کاملVerification of L-band Fully Polarimetric Noise Injection Radiometer Measurement Capability
Abstract A functional test to verify the proper and accurate measurement capability of an L-band fully polarimetric noise injection radiometer is presented. The test is designed specifically for the MDPP-2 (MIRAS Demonstrator Pilot Project 2) NIR (Noise Injection Radiometer), which has two functions: (1) to calibrate the MIRAS (Microwave Imaging Radiometer using Aperture Synthesis) instrument b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -