MRI-guided coupling for a focused ultrasound system using a top-to-bottom propagation
نویسندگان
چکیده
BACKGROUND A novel magnetic resonance imaging (MRI)-conditional coupling system was developed that accommodates a focused ultrasound (FUS) transducer. With this coupling system, the transducer can access targets from top to bottom. The intended clinical application is treatment of fibroids using FUS with the patient placed in supine position. METHODS The coupling system was manufactured using a rapid prototyping device using acrylonitrile butadiene styrene (ABS) plastic. Coupling to a gel phantom was achieved using a water bag filled with degassed water. The FUS transducer was immersed in the water bag. RESULTS The coupling system was successfully tested for MRI compatibility using fast-gradient pulse sequences in a gel phantom. The robotic system with its new coupling system was evaluated for its functionality for creating discrete and multiple (overlapping) lesions in the gel phantom. CONCLUSIONS An MRI-conditional FUS coupling system integrated with an existing robotic system was developed that has the potential to create thermal lesions in targets using a top-to-bottom approach. This system has the potential to treat fibroid tumors with the patient lying in supine position.
منابع مشابه
PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملTargeted Delivery of GDNF through the Blood–Brain Barrier by MRI-Guided Focused Ultrasound
Neurotrophic factors, such as glial cell line-derived neurotrophic factor (GDNF), are promising therapeutic agents for neurodegenerative diseases. However, the application of GDNF to treat these diseases effectively is limited because the blood-brain barrier (BBB) prevents the local delivery of macromolecular therapeutic agents from entering the central nervous system (CNS). Focused ultrasound ...
متن کاملMRI-guided focused ultrasound surgery for uterine fibroid treatment: a cost-effectiveness analysis.
OBJECTIVE. The purpose of this article is to evaluate the cost effectiveness of a treatment strategy for symptomatic uterine fibroids that uses MRI-guided focused ultrasound as a first-line therapy relative to uterine artery embolization (UAE) or hysterectomy. MATERIALS AND METHODS. We developed a decision-analytic model to compare the cost effectiveness of three first-line treatment strategies...
متن کاملA Numerical Investigation of the Time Reversal Mirror Technique for Trans-skull Brain Cancer Ultrasound Surgery
Introduction: The medical applications of ultrasound on human brain are highly limited by the phase and amplitude aberrations induced by the heterogeneities of the skull. However, it has been shown that time reversing coupled with amplitude compensation can overcome these aberrations. In this work, a model for 2D simulation of the time reversal mirror technique is proposed to study the possibil...
متن کاملCan magnetic resonance image-guided focused ultrasound surgery replace local oncology treatments? A review.
Magnetic resonance image-guided focused ultrasound surgery (MRgFUS) is an innovative technology in the new panorama of treatment using ultrasound. It combines two well-known and distinct methodologies: high-intensity focused ultrasound (HIFU) and a magnetic resonance imaging system (MRI). This review on MRgFUS is focused on the technical aspects and the current clinical applications in oncology...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2017