Bunch Length and Impedance Measurements at Spear3

نویسندگان

  • Jeff Corbett
  • Weixing Cheng
  • Alan S. Fisher
  • Xiaobiao Huang
چکیده

Streak camera measurements were made at SPEAR3 to characterize longitudinal coupling impedance. For the nominal optics, data was taken at three rf voltages and a single-bunch current range of 0-20mA. Both bunchcentroid phase shift and bunch lengthening were recorded to extract values for resistive and reactive impedance. An (R+L) and a Q=1 model were then back-substituted into the Haissinski equation and compared with raw profile data. In the short bunch (low-α) mode, distribution ‘bursting’ was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Streak-camera Measurements with High Currents in Pep-ii and Variable Optics in Spear3

A dual-axis, synchroscan streak camera was used to measure longitudinal bunch profiles in three storage rings at SLAC: the PEP-II lowand high-energy rings, and SPEAR3. At high currents, both PEP rings exhibit a transient synchronous-phase shift along the bunch train due to RF-cavity beam loading. Bunch length and profile asymmetry were measured along the train for a range of beam currents. To a...

متن کامل

Commissioning the Spear3 Diagnostic Beamlines

SPEAR3 has two diagnostic beam lines: an x-ray pinhole camera and a visible/UV beam line. The pinhole camera images ~8 keV dipole synchrotron radiation (SR) incident on a phosphor screen. The visible beam line delivers conventional optical radiation to an array of cameras and diagnostic elements on a 1x3m optical bench. This paper briefly reviews the pinhole camera system while concentrating mo...

متن کامل

Observation of Beam Ion Instability in Spear3*

Weak vertical coupled bunch instability with oscillation amplitude at μm level has been observed in SPEAR3. The instability becomes stronger when there is a vacuum pressure rise by partially turning off vacuum pumps and it becomes weaker when the vertical beam emittance is increased by turning off the skew quadrupole magnets. These confirmed that the instability was driven by ions in the vacuum...

متن کامل

Transverse Impedance Measurement in Rhic and the Ags

The RHIC luminosity upgrade program aims for an increase of the polarized proton luminosity by a factor 2. To achieve this goal a significant increase in the beam intensity is foreseen. The beam coupling impedance represents a source of detrimental effects for beam quality and stability at high bunch intensities. In this paper, we evaluate the global transverse impedance in both the AGS and RHI...

متن کامل

Impedance Analysis of Bunch Length Measurements at the ATF Damping Ring

We present energy spread and bunch length measurements at the Accelerator Test Facility (ATF) at KEK, as functions of current, for different ring rf voltages, and with the beam both on and off the coupling resonance. We fit the on-coupling bunch shapes to those of an impedance model consisting of a resistor and an inductor connected in series. We find that the fits are reasonably good, but that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008