Ureteric Injury due to the Use of LigaSure
نویسندگان
چکیده
Background. LigaSure is a bipolar clamping device used in open and laparoscopic surgeries for producing haemostasis in vascular pedicles up to 7 mm in diameter ("Covidien LigaSure technology: consistent, reliable, trusted vessel sealing," 2012). The use of LigaSure has made securing haemostasis and tissue dissection relatively easy especially in laparoscopic surgery; however, if not used with care it can cause damage to the surrounding structures through lateral spread of energy. Case Report. This case report discusses the induction of a thermal ureteral injury associated with the use of LigaSure. An 80-year-old gentleman was operated for bowel cancer. LigaSure was used for securing haemostasis and tissue dissection. Postoperatively, he was found to have damage to the right ureter secondary to lateral spread of energy from the jaws of LigaSure with high abdominal drain output. Conclusion. Judicious and careful use of electrosurgical devices should be done to prevent inadvertent damage to the surrounding structures. Early recognition and involvement of a urologist can prevent long-term complications.
منابع مشابه
Detecting aorto-ureteric fistula by 99mTc-Labeled Red Blood Cell SPECT
A 68-year-old male, known case of abdominal aortic dissection and recent aortic stent insertion, presented with gross hematuria. The urologists suspected aoro-ureteric fistula and performed open surgery (ureterolysis). Tc-99m labeled red blood cell (99mTc-RBC) scintigraphy was ordered to confirm the diagnosis and localize the possible aorto-ureteric fisula, Considering sustained gros...
متن کاملمقایسه کاربرد Ligasure با Stapler خطی در رزکسیون و ترمیم روده
Background: Regarding the limited number of studies on the feasibility of resection and repair of the small intestine by ligasure, we performed this study to compare ligasure with linear stapler for the previously mentioned operation.Methods: This phase 1 clinical trial study was performed in Ghaem Hospital, an educational hospital affiliated to Mashhad University of Medical Sciences, from 2010...
متن کاملProphylactic Ureteric Catheterization with Illuminated Ureteric Stent during Difficult Laparoscopic Colorectal Surgeries
Background: The close proximity of ureters to the colon and rectum, ureteric injury is a potential complication in colorectal surgery. Incidence of iatrogenic ureteric injury ranges from 1 to 10%. Aim: The aim of this study is to evaluate the operative time, the efficacy in preventing iatrogenic ureteric injuries and the complications associated with prophylactic illuminated ureteric catheteriz...
متن کاملIatrogenic ureteric and bladder injuries in obstetric and gynaecologic surgeries.
OBJECTIVE To review iatrogenic ureteric and urinary bladder injuries from obstetric and gynaecological surgeries treated in the urology department analysing; ureteric anatomy, aetiologic factors, diagnosis, treatment and outcomes. DESIGN A retrospective study. SETTING Institute of Urology, Kilimanjaro Christian Medical Center (KCMC), Moshi, Tanzania. SUBJECTS Twenty three women were treat...
متن کاملUse of the LigaSure in Cervicofacial Venous Malformation Excision
Complete surgical excision of venous malformations (VMs) is frequently complicated by massive bleeding and nerve damage, particularly in the cervicofacial area. This report describes a novel technique for the resection of cervicofacial VMs using the LigaSure (Valleylab, Tyco International Healthcare, Boulder, CO) vessel sealing system. We report three cases of VM excision using this vessel seal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2013 شماره
صفحات -