Measurement of choroidal melanoma basal diameter by wide-angle digital fundus camera: a comparison with ultrasound measurement.

نویسندگان

  • Jacob Pe'er
  • Cristhian Sancho
  • Jorge Cantu
  • Sheerlee Eilam
  • Israel Barzel
  • Marina Shulman
  • Eytan Z Blumenthal
چکیده

PURPOSE To compare the measurement of the basal diameter of choroidal melanoma, an important parameter for planning treatment and as a prognostic factor, by standardized ophthalmic ultrasound versus that obtained using a wide-angle fundus camera. METHODS The longest and shortest basal diameters of 104 consecutive choroidal melanomas of patients seen at the ocular oncology service of the Hadassah University Hospital were measured by B-scan ultrasound and compared with those measured by a wide-angle fundus camera (Panoret-1000). Each diameter was measured thrice by two ophthalmic photographers, and intra-observer and interobserver reproducibility were calculated as well. RESULTS The measurements of both the long and short diameters of the choroidal melanomas were significantly larger when measured by Panoret-1000 as compared with the B-scan ultrasound. There was no significant difference among the three measurements of each of the photographers. The interobserver reproducibility between the two photographers was high. CONCLUSIONS Our findings can be attributed to the larger extent of the pigmentation of the melanoma compared to its recognized elevation. Since pigmentation of choroidal melanoma is easier to recognize than its elevation, we assume that measurement by a wide-angle fundus camera is more accurate in pigmented tumors, and should be adopted for measuring the basal diameter of choroidal melanomas in planning treatment and follow-up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional ultrasound for the measurement of choroidal melanomas.

OBJECTIVE To evaluate the reliability of 3-dimensional ultrasound (3D-US) for the measurement of choroidal melanomas. DESIGN Retrospective case series. PARTICIPANTS Forty-two consecutive cases of choroidal melanoma imaged with 3D-US. METHODS Tumor measurements obtained with ophthalmoscopy, transillumination, standard ultrasound techniques, 3D-US, and pathological studies. Tumor diameters,...

متن کامل

Decreased choroidal thickness in eyes with secondary angle closure glaucoma. An aetiological factor for deep retinal changes in glaucoma?

A decreased count of retinal photoreceptors all over the fundus and a loss of retinal pigment epithelium cells mainly in the parapapillary region have been reported to be associated with glaucoma. This study addressed the question whether this cell loss in the deep retinal layers may be connected with a change of the choroidal thickness in glaucomatous eyes. Histological sections of 12 eyes wit...

متن کامل

Study on Wicking Measurement in Thin Layer Textiles by Processing Digital Images

The purpose of this work is to assess and develop experimental techniques that allowwicking measurement over a wide range of textiles. Various kinds of fabrics, nonwoven layers and anelectro spinning nylon layer were used as the test materials. A syringe is used to drop a 0.02 g spot ofdistilled water on the sample and a digital camera to take pictures simultaneously. When the wickingprocess st...

متن کامل

The American Brachytherapy Society recommendations for brachytherapy of uveal melanomas.

PURPOSE This article presents the American Brachytherapy Society (ABS) guidelines for the use of brachytherapy for patients with choroidal melanomas. METHODS Members of the ABS with expertise in choroidal melanoma formulated brachytherapy guidelines based upon their clinical experience and a review of the literature. The Board of Directors of the ABS approved the final report. RESULTS Episc...

متن کامل

Indocyanine green angiograms of choroidal nevi. comparison between confocal and nonconfocal scanning laser ophthalmoscope and fundus video camera.

PURPOSE A fundus video camera and a nonconfocal scanning laser ophthalmoscope (SLO) detect direct light and indirect light, whereas a confocal SLO detects mostly direct light. Differences in confocal and nonconfocal SLO images and fundus video camera images are most likely due to their different optical systems. These differences were examined in indocyanine green (ICG) angiograms of a choroida...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde

دوره 220 3  شماره 

صفحات  -

تاریخ انتشار 2006