Intravenous angiography using digital video subtraction: intravenous cervicocerebrovascular angiography.

نویسندگان

  • P C Christenson
  • T W Ovitt
  • H D Fisher
  • M M Frost
  • S Nudelman
  • H Roehrig
چکیده

The clinical application of intravenous angiography to study the cervicocerebrovascular system using the digital video subtraction system described in a companion article is reported. About 0.75 ml/kg of a standard 76% iodine contrast solution is injected into an antecubital vein using a power injector. Then 15-20 exposures of the head and neck region at a 1/sec rate are made on the image intensifier. The images are recorded by a high performance video system and the output signal is digitized for subsequent computer manipulation. The subtraction images of these vessels produced by the computer show the vessels clearly, even though they contain very low concentrations of contrast media. Standard exposure factors of 75-80 kVp, 9-10 msec at 800-1,000 mA are used. Clinically pertinent features of the data alteration and flow through the system and the step-by-step computer procedures used to achieve and analyze the various forms of subtracted images are described. Five experimental and clinical cases demonstrate appropriate applications to cervicocerebrovascular disease: (1) evaluating the effects of surgical and medical therapy on atherosclerosis; (2) providing a screening angiographic test for patients with asymptomatic bruits and/or positive noninvasive studies; (3) evaluating patients who have significant generalized vascular disease either precluding or presenting hazardous contraindications to transarterial catheterization; (4) evaluating significantly aged patients in whom standard angiography has higher risk; and (5) evaluating currently asymptomatic patients who are medically at higher risk for developing atherosclerotic lesions. Numerous examples of the various types of image manipulations are presented: (1) linear subtraction; (2) logarithmic subtraction; (3) alterations of electronic contrast enhancement (map slope); (4) the usefulness of a series of angiographic images; and (5) the importance of multiple projections with this technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravenous angiography using digital video subtraction: x-ray imaging system.

An x-ray imaging system, using digital subtraction techniques, has been developed. The system requires: (1) high output generation equipment; (2) an image intensifier capable of receiving high output exposures, 1 mR (2.58 X 10(-7) C/kg) at the face of the intensifier, without loss of either contrast or resolution; (3) a precision digital video camera; (4) processing computer with sufficient sto...

متن کامل

Intravenous digital subtraction angiography of the nearly occluded internal carotid artery.

Three patients with nearly occluded internal carotid artery origins were evaluated with intravenous digital subtraction angiography and subsequently had successful carotid endarterectomies. The angiographic features are described. Although conventional arterial angiography offers superior spatial resolution and selectivity, the thorough mixing of blood and contrast medium that occurs with the i...

متن کامل

Intravenous 3D digital subtraction angiography in the diagnosis of unruptured intracranial aneurysms.

Recent progress in digital subtraction angiography (DSA) devices makes it possible to perform rotational angiography with high resolution and high sensitivity. We tried intravenous (IV) 3D DSA in patients who had undergone MR angiography (MRA) suggestive of unruptured intracranial aneurysms. IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suggested o...

متن کامل

Low-cost digital subtraction angiography.

Intravenous angiography was an important diagnostic tool earlier in th is century [1] , however, the technique had many drawbacks . Film timing was critical, the volume of contrast material was high , and the contrast resolution was often poor. When safer techniques for direct arteriography were developed, intravenous angiography was abandoned . Computed digital image processing has brought a r...

متن کامل

Omnipaque vs. Hexabrix in intravenous DSA of the carotid arteries: randomized double-blind crossover study.

A randomized double-blind crossover study using Omnipaque 350 mg l/ml (iohexol) and Hexabrix 320 mg l/ml (ioxaglate) in 53 patients undergoing intravenous digital subtraction angiography of the carotid arteries revealed no significant differences in image quality. Some differences were found in subjective side effects that favored Omnipaque. Nausea was reported in four patients after injection ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 135 6  شماره 

صفحات  -

تاریخ انتشار 1980