A novel technique for measurement of pericardial pressure.

نویسندگان

  • G deVries
  • D R Hamilton
  • H E Ter Keurs
  • R Beyar
  • J V Tyberg
چکیده

To determine whether pericardial liquid pressure accurately measures pericardial constraint, we developed a technique in which a catheter was positioned perpendicular to the epicardial surface. This device, which occupies little or no pericardial space, couples the thin film of liquid to a transducer. In six open-chest dogs, we also measured left ventricular (LV) end-diastolic pressure (LVEDP) and anteroposterior and septum-to-free wall diameters. LVEDP was raised incrementally to approximately 25 mmHg by saline infusion. With the use of the product of the two diameters as an index of area (A(LV)), LVEDP-A(LV) relationships were obtained with the pericardium closed and again after the pericardium had been widely opened to obtain the isovolumic difference in LVEDP (DeltaLVEDP). In all dogs, the technique yielded values of pericardial pressure equal to DeltaLVEDP as well as equal to that measured using a previously placed balloon transducer in the same location and at the same A(LV). We conclude that, when the pressure of the pericardial liquid is appropriately measured, it (in addition to the balloon-measured contact stress) defines the diastolic constraining effect of the pericardium. Furthermore, we suggest that earlier measurements of pericardial "liquid pressure" were low, due to an artifact of measurement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of pericardial constraint: the relation between right ventricular filling pressure and pericardial pressure measured after pericardiocentesis.

Experimental studies have shown that right ventricular filling pressure (that is, intracavitary diastolic pressure) approximates pericardial surface pressure but, in many patients after removal of pericardial effusion, right ventricular filling pressure has been found to markedly exceed pericardial pressure recorded by an open catheter. The aim of this study was to determine whether this appare...

متن کامل

Measurement of postoperative pericardial pressure in man.

Pericardial pressure was measured in 18 patients undergoing cardiopulmonary bypass for up to 10 days using a solid state transducer. Mean and phasic pericardial pressure wave forms were similar to those reported in animals. A wide range of mean pressure from 0 to 30 mmHg was recorded, and values of up to 20 mmHg were observed in patients whose postoperative clinical course was uncomplicated. Fl...

متن کامل

Comparison of the prevalence of pericardial effusion and cardiac tamponade after cardiac surgery with and without chest tube suction in patients referred to Chamran hospital, Isfahan

Background: Pericardial effusion is one of the most important complications of cardiac surgeries. Administration of a low-power suction to the mediastinal or pleural chest tube of patients helps better and constant drainage of pericardial or pleural secretions after surgeries. This technique might change the secretion and discharges of patients and might change the outcomes of surgeries. Metho...

متن کامل

Nonuniform regional deformation of the pericardium during the cardiac cycle in dogs.

We hypothesized that local contact forces between the pericardium and the heart cause regional variation in pericardial deformation during the cardiac cycle, reflecting volume changes of the underlying cardiac chambers. To test this, we measured regional pericardial area over the right atrium (RA) and right ventricle (RV) with orthogonal pairs of sonomicrometers in six open-chest dogs. At a lef...

متن کامل

Direct assessment of right ventricular transmural pressure.

Although the measurement of transmural pressure is important, calculation of transmural pressure is complicated by the difficulties in measuring pericardial pressure. Recently, flat balloons have been proposed to measure pericardial pressure. Over a wide range of volumes, right ventricular diastolic pressure and pericardial balloon pressure were similar in diastole, suggesting that the right ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 280 6  شماره 

صفحات  -

تاریخ انتشار 2001