The performance of laboratories analysing heavy metals in the Workplace Analysis Scheme for Proficiency (WASP).

نویسنده

  • Peter R Stacey
چکیده

This paper discusses the proficiency of laboratories analysing identical test samples representative of metals in air in the Workplace Analysis Scheme for Proficiency (WASP) and the variability of results from laboratories used to assess personal exposure in the workplace. Over 11 years, the performance of laboratories has significantly improved for lead, cadmium and chromium. Laboratories show better agreement when using inductively coupled plasma-atomic emission spectroscopy (ICP-AES) than flame atomic absorption spectroscopy (FAAS) when analysing chromium, but not when analysing lead and cadmium. Data from the proficiency testing scheme show that for a customer to have confidence that a measurement value does not exceed the workplace exposure limit the analytical result would have to be <134 microg m(-3) for lead and 23 microg m(-3) for cadmium for an 8 h sample and 129 microg m(-3) for lead, 21 microg m(-3) for cadmium and 429 microg m(-3) for chromium for a 4 h sample (for samples with relatively soluble matrices), before considering the further uncertainties due to sampling. The performance criterion for satisfactory performance (+/-8.3%) was found to be appropriate as long as laboratories participated consecutively in all rounds. Estimates of the overall uncertainty of results from ICP-AES and FAAS analysis were shown to meet the criteria in EN482. Samples from some types of workplace environments are more difficult than the WASP test material to dissolve into solution, so it is expected that estimates of uncertainty are larger for less soluble analytes and matrices. WASP has now initiated a programme to help laboratories assess their performance with more complex matrices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplac...

متن کامل

Investigating and Analysing Instructional Design and Workplace Learning Models and Selection of Adaptive Model to Optimize Organizational Training in Petrochemical Industry

The present research aimed to analyze instructional design,workplace learning, and selecting the optimum model of learning for human resources training in petrochemical industry.The previous roles have become faint and new opportunities have appeared in petrochemical industry by starting the process of privatization and changing the nature of the company from holding to a governance and develop...

متن کامل

Ranking Iranian Accredited Laboratories with Proficiency Tests Using PR0METHEE Method

The rapid pace of changing technology is leading to high rate of import and export between different countries. In outsourcing governmental organizations duties to private sectors, it is a need to control sectors and they should be under assessment policy. This research has been developed to show how the accredited laboratories of Iranian standard (ISIRI) can be assessed for their technical ser...

متن کامل

Health risk assessment of heavy metals, BTEX and polycyclic aromatic hydrocarbons (PAHs) in the workplace in a secondary oil re-refining factory

The present study aimed to evaluate the health risk of heavy metals (iron, zinc, cadmium, arsenic, nickel, lead, and mercury), benzene, toluene, ethylbenzene and xylene (BTEX), and polycyclic aromatic hydrocarbons (PAHs) in the workplace in a secondary oil re-refining factory. In this descriptive, cross-sectional study, samples were collected and analyzed using the NIOSH 1501 method at eight sa...

متن کامل

Application of Statistics to Evaluate Iranian Analytical Laboratories Proficiency: Case of Aflatoxins in Pistachio

The aim of this study was to evaluate the utility of a proficiency testing program among limited number of local laboratories as an alternative to the IUPAC/CITAC guide on proficiency testing with a limited number of participants, specially where international schemes are not accessible. As a sample scheme we planned to determine aflatoxins (B1, G1, B2, G2, total) in Iranian pistachio matrix. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 50 4  شماره 

صفحات  -

تاریخ انتشار 2006