Film thickness of resin cements used with adhesive systems.

نویسندگان

  • Vivian N Zahra
  • Pablo F Abate
  • Ricardo L Macchi
چکیده

The final film thickness of a resin adhesive and a resin cement could be affected by previous polymerization of the adhesive systems on dentin surfaces. The aim of this work was to evaluate changes in the film thickness of dual resin based cements with their adhesives as a function of polymerization of the latter on dentin surfaces. The materials used were: RelyX ARC (R) + Single Bond (SB) and Variolink base (VB) and high (HV) or low (LV) viscosity catalyst + Syntac Classic (S) or Excite DSC (E); 56 human dentin discs and 56 composite resin discs (Z250). Dentin disc surfaces were treated with 35% phosphoric acid (except for S) and the adhesive system was either polymerized or not polymerized. A 0.05 ml increment of cement mixture was placed on the dentin disc and covered with the resin disc. A 25 N load was applied for ten minutes and then, the combined thickness was measured with a digital micrometer. Sample size (n) was 4 for each cement or condition. A two-way analysis of variance was performed with a level of significance of p < 0.05. The mean film thickness (and standard deviations) in microm, with and without previous polymerization of the adhesive layer, were: R+SB: 16.50 (2.64) and 17.00 (1.41); VB+S: 21.75 (5.37) and 62.25 (0.95); VB LV+S: 24.50 (3.87) and 72.75 (1.89); VB HV+S: 28.75 (8.46) and 93.00 (53.63); VB+E: 31.75 (8.38) and 42.75 (4.34); VB LV+E: 47.75 (2.50) and 45.75 (3.20); VB HV+E: 49.25 (25.50) and 45.75 (2.75). Significant differences (p < 0.01) were found for the cements and polymerization condition as well as for the interaction between them. Instructions regarding polymerization of the adhesive layer must be followed when adhesive systems are used in combination with dual polymerized resin based cements. Otherwise, final film thickness of the adhesive and the resin cement could be affected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fracture Resistance of Lithium Disilicate Ceramics Bonded to Enamel or Dentin Using Different Resin Cement Types and Film Thicknesses.

PURPOSE To investigate the influence of cement film thickness, cement type, and substrate (enamel or dentin) on ceramic fracture resistance. MATERIALS AND METHODS One hundred extracted human third molars were polished to obtain 50 enamel and 50 dentin specimens. The specimens were cemented to 1-mm-thick lithium disilicate ceramic plates with different cement film thicknesses (100 and 300 μm) ...

متن کامل

Factors contributing to the incompatibility between new adhesive systems and various composite resin restorations

  Factors contributing to the incompatibility between new adhesive systems and various composite resin restorations     Dr. F. Maleknejad* - Dr. H. Moosavi**  *- Associate Professor of Operative Dentistry Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences.  **- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences.   ...

متن کامل

Microtensile Bond Strength of Self-Adhesive Luting Cements to Ceramics

The purpose of this paper was to compare the bond strengths of the self-adhesive luting cements between ceramics and resin cores and examine their relation to the cement thickness. Three self-adhesive luting cements (Smartcem, Maxcem, and G-CEM) and a resin cement (Panavia F 2.0) for control were used in the paper. The thickness of the cements was controlled in approximately 25, 50, 100, or 200...

متن کامل

Morphological and bond strength evaluation of different resin cements to root dentin.

This study correlated the morphological characteristics with the bond strengths of various resin cements used for bonding fiber posts to root canal dentin. Fifty glass-fiber posts (FRC Postec Plus) were luted into the root canals of extracted human anterior teeth using five resin cements (n = 10): Panavia F 2.0, PermaFlo DC, Variolink II, RelyX Unicem, and Clearfil Core. Before insertion of the...

متن کامل

Film Thickness and Flow Properties of Resin-Based Cements at Different Temperatures

STATEMENT OF PROBLEM For a luting agent to allow complete seating of prosthetic restorations, it must obtain an appropriate flow rate maintaining a minimum film thickness. The performance of recently introduced luting agents in this regard has not been evaluated. PURPOSE To measure and compare the film thickness and flow properties of seven resin-containing luting cements at different tempera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta odontologica latinoamericana : AOL

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2008