Aspiration prevented by the ProSeal laryngeal mask airway: a case report.
نویسندگان
چکیده
PURPOSE To describe a case of intraoperative passive regurgitation where the ProSeal laryngeal mask airway (PLMA) successfully protected the airway from the respiratory tract. CLINICAL FEATURES A 32-yr-old man was electively scheduled for change of dressings and application of plaster of Paris to both legs. A size 5 PLMA was inserted on the first attempt and the patient allowed to breathe spontaneously. Twenty-five minutes into the procedure brown fluid was noticed in the drainage tube of the mask. There was no change in respiratory pattern nor any evidence of coughing retching or vomiting. Twenty-five millilitres of fluid were suctioned out of the tube which tested positive for acid. The PLMA was left in place and the procedure continued uneventfully. After removal of the mask pH testing showed the dorsum of the mask to have a pH of 7 and the ventrum/bowl of the mask to be dry with a pH of 7. The patient had no respiratory symptoms in the recovery room and the postoperative course was uneventful. CONCLUSIONS This case illustrates that passive regurgitation can occur unexpectedly intraoperatively and shows that the PLMA can protect the airway during such an event by allowing the regurgitated fluid to pass up the drainage tube without leaking into the glottis.
منابع مشابه
Protection from aspiration with the LMA-ProSeal after vomiting: a case report.
PURPOSE To describe a case of vomiting with a laryngeal mask airway ProSeal(TM) (PLMA) in situ. The new design features of the PLMA and their role in protection from aspiration are discussed. CLINICAL FEATURES A 27-yr-old female underwent bilateral reduction mammoplasty under general anesthesia utilizing a PLMA for airway management. During transfer to the postanesthesia care unit, she had an...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملEsophageal aspiration of air through the drain tube of the ProSeal laryngeal mask.
IMPLICATIONS Two patients experienced partial upper airway obstruction while breathing spontaneously with the ProSeal laryngeal mask airway. This resulted in esophageal aspiration of air through the drain tube.
متن کاملUse of the ProSeal laryngeal mask airway in an infant with a repaired H-type tracheoesophageal fistula and tracheomalacia.
The ProSeal laryngeal mask airway (PLMA) is a relatively new airway device with design features that improve the quality of positive pressure ventilation (PPV) and may decrease the risk of gastric aspiration. We describe the use of this device for the anesthesia management of an infant with an esophagocutaneous fistula following repair of an H-type tracheoesophageal fistula and tracheomalacia, ...
متن کاملLaryngospasm as a Cause of Unsuccessful Placement of Laryngeal Mask Airway ProSeal: A Case Report.
Laryngospasm is a potential complication encountered during anesthesia using a laryngeal mask airway (LMA). We report a case in which laryngospasm resulted in unsuccessful placement of an LMA ProSeal Airway (Teleflex Inc), and we discuss the various causes of unsuccessful placement of this type of airway device. Laryngospasm causes increased resistance to gas flow by inducing closure of vocal c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2002