Success of ultrasonic technique in removing fractured rotary nickel-titanium endodontic instruments from root canals and its effect on the required force for root fracture.

نویسندگان

  • Hasan Shahabinejad
  • Amirreza Ghassemi
  • Lida Pishbin
  • Arash Shahravan
چکیده

INTRODUCTION Fracture of rotary nickel-titanium files is a real concern among endodontists; it affects the long-term prognosis of treatment. Ultrasound is a favorable technique for removing broken files, although it may result in some complications. The aim of this study was to determine the success rate of ultrasonic technique in removing file fragments and to evaluate its influence on the force required to fracture a tooth root. METHODS An in vitro study was carried out on 70 extracted maxillary premolars. In the experimental group a #30/.04 taper Hero file was guided into the canal to break and lodge therein. The lodged file was removed by ultrasonic vibration and use of a dental operating microscope. The canals were instrumented with Hero files by using crown-down technique and then obturated. All the teeth were prepared for mechanical testing in Testometric machine to measure the required force for root fracture. The Fisher exact test and independent two-sample t test were used to analyze data. RESULTS Ultrasonic technique exhibited a success rate of 80% in removing broken files. Success rate in the roots with file fracture before the curve was 11.5 times more than that of file fracture cases beyond the curve. Other factors such as bypass possibility did not affect success rate. The average time required for removing file fragments was 36.3 ± 7.15 minutes, which did not significantly differ in different file locations within the canal. According to mechanical test results, ultrasonic application did not significantly affect the required force for root fracture. The force required to fracture a root did not significantly differ in various file locations. Vertical fracture in the buccolingual direction (split tooth) was the most incident fracture pattern. Procedural errors observed in this study predominantly included transportation, perforation, and craze line. CONCLUSIONS Ultrasonic technique was successful in removing 80% of fractured rotary files and did not significantly affect the required force for root fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases.

The removal of fractured rotary nickel-titanium instruments from small, curved root canals is one of the most complex operative procedures in endodontics. There have been many different devices and techniques developed to remove fractured instruments, but none are consistently successful and all show a high incidence of canal damage such as perforation. A technique using a staging platform and ...

متن کامل

Ultrasonic Treatment Endodontice

The aim of this study is to demonstrate the ability of our ultrasonic endodontic dental device with rotary nickel-titanium alloy instruments for the root canal treatment. This study is aimed at investigating the cleaning and shaping efficacy with “Ultrasonic device for endodontic treatment of dental’s canals. The purpose of root canal treatment is to get rid of the damaged pulp and the bacteria...

متن کامل

ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy.

AIM To investigate physical parameters for ProTaper nickel-titanium (NiTi) rotary instruments whilst preparing curved canals in maxillary molars in vitro. METHODOLOGY A novel torque-testing platform was used to prepare root canals in 15 extracted human maxillary molars with ProTaper rotary instruments. Peak torque and force was registered along with numbers of rotations required to shape the ...

متن کامل

Tips to avoid instrument separation in endodontics.

procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...

متن کامل

Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals

Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 2013